255-700-019
4-13
PacketStar
™
PSAX 20 Access Concentrator User Guide
, Issue 1
Release 6.3.0
Chapter 4 Configuring the Basic System
Configuring the System for Your Site
Begin
Viewing OAM Properties
1
Select the values for the fields in the Master ATM Address and OAM
related data panel as described in Table 4-1.
2
Select the
Apply Site-Specific Configuration
command and press Enter.
3
To return to the Console Interface Main Menu window, press
Ct r l+B
.
End
Table 4-1. Field Values for Master ATM Address and OAM Related Data
Panel
Field
Description
Master Node Addr
Enter the master node address to where
the traps will be sent (10 octets).
Address Type
Select an address type from the pull-
down menu:
Nsap,
E164
, or
E164nsap.
Loopback Location ID
Enter the unique identifier of the ATM
node where the loopback is to occur (8
octets).
Loopback Location ID
is the location
identifier of the local switch. It is used as
"Source Location Id" in all the outgoing
OAM loopback cells and will be com-
pared with the "Destination Location Id"
of a received OAM loopback cell to decide
if the received OAM loopback cell should
be looped back by this switch or not.
You must enter a unique value in the
Loopback Location ID
field to perform
OAM loopback tests.
(For more information about OAM loop-
back tests, see Chapter 5, "Using System
Diagnostics.”)
Debouncing Period
Enter a value between
1000
and
300000
(default value is
2000
).
This field is used in OAM; it is the maxi-
mum time (in milliseconds) for clearing
OAM AIS and RDI alarms.
Summary of Contents for PacketStar PSAX 20