Power Up: DLP-510
363-205-401
Page 4 of 4
Issue 7, March 1997
6.
NOTE:
Each 40D BFU fuse bead, except the yellow fuse beads, will pop out
when the fuse blows. The AUG11 ALM indicator light and the fuse flag
pops out when the fuse blows.
Do any fuses on BFU blow?
If YES, then continue with Step 7.
If NO, then proceed to Step 10.
7.
Replace blown fuse(s) on AUG11 BFU using WP90247 L201 Inser-
tion/Extraction tool; or WECO 553A Extractor Tool (Techni-Tool No.
594TE170) or WECO 319B (KS-6305) Extractor Tool (Techni-Tool No.
490PL020) for the 40D BFU.
8.
Do any fuses on BFU blow?
If YES, then continue with Step 9.
If NO, then proceed to Step 10.
9.
Check wiring using SD-7C130-01 or SD-7C119-01.
10. Is another BFU to be installed at this time?
If YES, then continue with Step 11.
If NO, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
11. Repeat the procedure from Step 3 for next BFU to be installed.