Power Up: DLP-533
363-205-401
Page 6 of 6
Issue 7, March 1997
31. Note that battery being used is defective.
32. After 15 minutes, does COMPLETE indicator light?
If YES, then continue with Step 33.
If NO, then proceed to Step 34.
33. Unplug battery. Store connector head in test set cover. Reinstall cover.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
34.
!
DANGER:
A high discharge current is present at connector head if TESTING
indicator is lighted. Batteries must not be connected or disconnected
when TESTING indicator is lighted.
Defective test set. Depress STOP button, unplug battery. Return test set for
repair.
35. Defective test set. Return for repair.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.