363-205-401
RT Turn Up:
Issue 7, March 1997
Page 1 of 6
NTP-006
Turn Up Series 5 RT Blue or White System Equipped
for Feature Package 303
DO ITEMS BELOW IN ORDER LISTED
FOR DETAILS, GO TO
SUMMARY: Use this procedure to turn up Feature Package 303 (FP303) in the blue
(lower) or white (upper) system of a dual channel bank. The A and C line interface
unit (LIU) DS1 facilities carry the active and standby embedded operations channel
(EOC) and timeslot management channel (TMC) for a system; therefore, the
minimum turn up must include both of these facilities. B and/or D LIU DS1 facilities
can also be equipped now or at a later time. BCU and TRU Release 3.0 firmware
accommodates the Common Management Information Protocol (CMIP-91) version.
The term "facility shelf" is used throughout this procedure to refer to the middle shelf
of the Series 5 RT. The remaining shelves will be referenced according to digroup
name (for example, the shelf containing digroups A and B is referred to as the AB
shelf). The white system refers to the two upper shelves of the Series 5 RT plus the
right half of the facility shelf; the blue system refers to the two lower shelves of the
Series 5 RT plus the left half of the facility shelf.
1.
Get support equipment listed:
• 216-type tool (80-type cabinet only)
• Special key (allen-type wrench) - COMCODE 846244168
(51- and 80-type cabinet only)
• DMM (digital multimeter) with an accuracy of 1.0% and an
AC/DC input impedance of
≥
1 megohm.