RT Turn Up: DLP-505
363-205-401
Page 2 of 6
Issue 7, March 1997
• 8 - On AUB21, toward number if MISC2 is to report a major alarm or away
from number if MISC2 is to report a minor alarm. Unused on AUB24.
Figure 1 – AUB21 and AUB24 RT ADU Option Switch Settings
MJ
FAIL
MN
FE
AUB_
S3
1
2
3
4
5
6
7
8
AB IN-SERVICE
CD IN-SERVICE
AB EQUIPPED
PROTECTION LINE
AB PRE-SERVICE
CD PRE-SERVICE
AB UNEQUIPPED
1
2
3
4
5
6
7
8
(S2)
NE
LED
TEST
ADU
(NOTE 1)
NOTE:
1. OPEN WHEN DEPRESSED AWAY FROM THE NUMBER
CLOSED WHEN DEPRESSED TOWARDS THE NUMBER
CD UNEQUIPPED
FUSE
CD EQUIPPED
MJ ALARM-RT MISC1 (AUB21)
MJ ALARM-RT MISC2 (AUB21)
UNUSED (AUB24)
MN ALARM-RT MISC1 (AUB21)
AUB21 and AUB24 SWITCH SETTINGS
CLOSED
S2
OPEN
NO PROTECTION
MODE 2 (AUA24 ONLY)
16 BIT ALARM FIELD (AUB24)†
DS1 (AUA21)*; MODE 1 (AUA24 ONLY)
13 BIT ALARM FIELD (AUB24)‡
MN ALARM-RT MISC2 (AUB21)
UNUSED (AUB24)
* Always set switch 2 on AUB21 to OPEN.
‡ Always set switch 7 on AUB24 to OPEN.
† Reserved for future use.