363-205-401
RT Turn Up:
Issue 7, March 1997
Page 1 of 6
DLP-507
Option and Install AUB26 ADU
SUMMARY: Set the ADU options for the system configuration (positions 1,2,7, 8,
and 9) with AB and CD set to pre-service and unequipped (positions 3-6 open). Install
ADU, then BCU and verify no alarms. Remove ADU and set AB (and CD if required)
to equipped (positions 2 and 3). Reinstall ADU and disregard alarms.
1.
Has the BCU been installed?
If NO, then continue with Step 2.
If YES, then proceed to Step 7.
2.
Get one AUB26 (Feature Package C or Feature Package D) and inspect for
possible damage.
3.
Verify that fuse on ADU is not blown. If fuse is blown, get another ADU that
contains good fuse.
4.
On AUB26 ADU option switch S1 (Figure 1), use an orange stick (KS-6320,
L1) or equivalent and set switch positions as follows:
• 1 - Toward PL for protection switching or toward NPL for no protection
switching.
• 2 - Toward 32 if system is FPD. Otherwise, set it toward 64.
• 3 - Toward ABP.
• 4 - Toward CDP.
• 5 - Toward ABU.
• 6 - Toward CDU.
• 7 - Toward 1MJ if MISC1 is to report a major alarm or toward 1MN if
MISC1 is to report a minor alarm.
• 8 - Toward 2MJ if MISC2 is to report a major alarm or toward 2MN if
MISC2 is to report a minor alarm.
• 9 - Toward D4.
• 10 - Toward D4.