RT Turn Up: DLP-516
363-205-401
Page 2 of 4
Issue 7, March 1997
11. Did FAIL indicator on CTU light momentarily?
If YES, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then continue with Step 12.
12.
!
CAUTION:
Incorrectly set ADU option switches may result in immediate or future
loss of service or may introduce errors into the digital bitstream.
Replace ADU with another correctly optioned ADU.
13. Wait 20 seconds and then replace CTU with CTU removed previously while
observing FAIL indicator on CTU faceplate.
14. Did FAIL indicator on CTU light momentarily?
If YES, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then continue with Step 15.
15.
!
CAUTION:
Incorrectly set ADU option switches may result in immediate or future
loss of service or may introduce errors into the digital bitstream.
Replace ADU with ADU removed previously.
16. Are any fuses on CFU in blue (lower) bank blown?
If YES, then continue with Step 17.
If NO, then proceed to Step 20.
17. Replace blown fuse(s) on CFU.
18. Unseat, then reseat CTU while observing FAIL indicator on CTU faceplate.
19. Does FAIL indicator on CTU light momentarily?
If YES, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then continue with Step 20.
20. Replace CFU in blue bank.
21. Unseat, then reseat CTU while observing FAIL indicator on CTU faceplate.