363-205-401
RT Turn Up: DLP-525
Issue 7, March 1997
Page 3 of 4
12.
!
CAUTION:
Incorrectly set ADU option switches may result in immediate or future
loss of service or may introduce errors into the digital bitstream.
Replace ADU with another correctly optioned ADU.
Reference:
DLP-523
13. Wait 20 seconds and then replace LSU with the LSU removed previously
while observing FAIL indicator on LSU faceplate.
14. Did FAIL indicator on LSU light momentarily and go off?
If YES, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then continue with Step 15.
15. Replace ADU with ADU removed previously.
16. Check wiring using SD-7C117-01 or SD-7C117-02. Repeat procedure from
Step 3 after locating and correcting trouble.