363-205-401
DT Turn Up:
Issue 7, March 1997
Page 1 of 4
DLP-500
Turn Up or Add Customer DC Back Powering For
900A2 or 900A3 Distant Terminal
1.
Use a 216C tool to open (loosen the lock nuts and pivot the top over) the ped-
estal containing 900A2, or 900A3 DTs and DC power module (Figure 1).
Comment: DT power cord connections, DC power protector installation,
and DC power pair connections can be made on an "as
required basis." The DC power feed pairs (and required pro-
tectors) should be connected top to bottom.
Figure 1 – Low Profile DT Pedestal with DC Back Powering
Locking Screw
Both Sides
Pivot Point
Pivot to Open
Lift to Remove
(After Pivoting)