363-205-401
Conversions:
Issue 7, March 1997
Page 1 of 4
DLP-501
Install AUB26 Alarm Display Unit (ADU) for FPC
Conversion
1.
Get one AUB26 ADU and inspect for possible damage.
2.
Verify that fuse on ADU is not blown. If fuse is blown, get another ADU that
contains good fuse.
3.
On ADU option switch S1 (Figure 1), use orange stick (KS-6320, L1) or
equivalent to set switch positions 1 through 8 to agree with the settings of the
switch positions on switch S2 (Figure 2) of the ADU removed previously. Set
switch position 9 to D4.
4.
!
CAUTION:
Incorrectly set ADU option switches may result in immediate or future
loss of service or may introduce errors into the digital bitstream.
Insert ADU into ADU slot.
Response:
Disregard all indicators that may be lighted.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.