Conversions: DLP-502
363-205-401
Page 2 of 2
Issue 7, March 1997
5.
Does FAIL indicator on BCU and ADU go off after approximately 20 sec-
onds?
If YES, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then proceed to Step 6.
6.
Replace BCU with another BCU.
7.
Does FAIL indicator on BCU and ADU go off after approximately 20 sec-
onds?
If YES, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then proceed to Step 8.
8.
Replace BCU with BCU removed previously.
9.
Check wiring using SD-7C117-01 or SD-7C117-02. Repeat procedure from
Step 2 after locating and correcting trouble.