363-205-401
Conversions: DLP-514
Issue 7, March 1997
Page 3 of 4
6.
!
CAUTION:
Line coding on the digital facility and terminal equipment interfaces
MUST BE THE SAME or service interruptions can result.
Set the line coding switch (S1 on the AUA61C or D or S100 on the AUA62C
or D or AUA64C or D) to B8ZS (Table C).
Table A
AUA61C or D
LIU Equalizer Settings
Distance
to DSX-1
Equalizer Switch
(S400/S2) Setting
(Feet)
2
1
0
0-132
133-265
266-398
399-532
533-655
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
ON
OFF
ON
OFF
ON
Table B
AUA62C or D and AUA64C or D LIU Transmit/Receive Pad Setting
Inserted
Loss
Transmit Pad (S400/S1, S2)
Switch Settings
Receive Pad (S100)
Switch Settings
(dB)
1
2
3
4
1
2
22.5
15.0
7.5
0
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
—
—
OFF
ON*
—
—
ON*
OFF
* ON when depressed toward the numbers.