Power Up: DLP-501
363-205-401
Page 2 of 4
Issue 7, March 1997
12. Check wiring on rear of power shelf using SD-7C119-01 and check AC power
connections at dual bank assembly. Repeat procedure from Step 4 after locat-
ing and correcting trouble.
13. Remove DMM test leads from LDU.
14. Is ED7C613-30, G2 order wire build-out resistance module to be installed?
If YES, then continue with Step 15.
If NO, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
15. Is RT assembly installed in frame or cabinet?
If FRAME, then proceed to Step 17.
If CABINET, then continue with Step 16.
16. Insert ED7C613-30, G2 order wire build-out resistance module into slot in LDU
faceplate and proceed to Step 18.
17. At miscellaneous pair panel, pull top of faceplate forward to expose top of unit
and insert ED7C613-30, G2 order wire build-out resistance module into slot
located in top of unit on left side.
18. Set switches on order wire build-out resistance module per engineering
records (Figure 1).
STOP. YOU HAVE COMPLETED THIS PROCEDURE.