363-205-401
Power Up:
Issue 7, March 1997
Page 1 of 4
NTP-006
Turn Up J1C182BD Power Shelf in 80A Cabinet
DO ITEMS BELOW IN ORDER LISTED
FOR DETAILS, GO TO
1.
NOTE:
This procedure provides steps for the initial installation of the
J1C182BD power shelf and supporting equipment in an
80A-type cabinet.
This procedure assumes the following;
•
The outside cable pairs are not connected through to
the RT (protectors not installed) so that the RT is iso-
lated from the digital lines and derived pairs.
•
The cabinet housing the RT has been installed.
•
The applicable acceptance Tab procedures in this vol-
ume have been performed.
This procedure contains instructions concerning the installation of
batteries into the cabinet and the various units into the J1C182BD
power shelf assembly, and for verifying that the units are operat-
ing properly prior to turning up RT channel banks or other carrier
facility shelf equipment.
2.
Get support apparatus listed:
• 216-type tool,
• Special key (modified hex key) - COMCODE 846244168,
• DMM (digital multimeter) with an accuracy of 0.02% and an
AC/DC input impedance of
≥
1 megohm,
• Permanent marker or equivalent (for battery installation).
• One AUA11( ) PCU (power converter unit).