22
Stinger OC12-ATM Trunk Module Guide
Configuring the OC12-ATM Trunk Module
Checking daughter card status
admin>
list 1
[in SONET-STAT/{ shelf-1 trunk-module-2 1 }:interval-performance-
monitoring[1]]
sonet-section-errored-seconds = 0
sonet-section-severely-errored-seconds = 0
...
sonet-far-end-path-unavailable-seconds = 0
Checking daughter card status
The Stinger unit creates a
trunk-daughter-dev
profile for the daughter card of a trunk
module when the module is initialized. This profile provides read-only information
about type of daughter card installed and its operational status.
The following display shows the
trunk-daughter-dev
parameters for the daughter
card of an OC12-ATM module:
[in TRUNK-DAUGHTER-DEV/{ shelf-1 trunk-module-1 1 }]
device-address* = { shelf-1 trunk-module-1 1 }
device-state = trunk-daughter-oper-state-up
trunk-daughter-type = trunk-daughter-oc12
previous-trunk-daughter-type = trunk-daughter-none
transceiver-info = { reach-none interface-oc12 }
Parameter
Indicates
device-address
Physical location of the Stinger system’s OC12-ATM
module, on which the daughter card is mounted.
device-state
The operational state of the daughter card. One of the
following will be displayed:
■
trunk-daughter-oper-state-down
—The device is
in a non-operational state.
■
trunk-daughter-oper-state-up
—The device is
operating normally.
■
trunk-daughter-oper-state-none
—The device is
not detected, the daughter card slot is empty.