1-16
Stinger® ADSL 48-Port Annex A LIM Guide
Configuring an ADSL 48-Port Annex A Line Interface Module (LIM)
Configuring call control
Configuring call control
Using the call-control procedures, you can configure the Stinger to allow connections to be
established even when the line state is not fully up. You configure the unit to use these
procedures systemwide or on a per-port basis on the DS3-ATM, OC3-ATM, and E3-ATM
trunk modules and on the SDSL, ADSL, and SHDSL/HDSL2 LIMs.
The call control mechanism enables the Stinger unit to establish and maintain soft PVCs
(SPVCs) across port state changes. This allows xDSL subscribers to establish connections on
LIM interfaces in the operating states before the interfaces are fully trained, as well as in the
standard
port-up
state (in which the modem has successfully trained). SPVC connections
are accepted when the modem has not fully trained up to the
port-up
state. If a LIM
interface with an active SPVC connection changes from a
port-up
state to the state it was in
before it was fully trained, the SPVC remains connected. Connections are broken only if the
physical slot or line stops operating or is disabled by an administrator.
By default, the Stinger unit monitors the physical line state of its interfaces and allows
connections to be established only when the line state is fully connected.
Following are examples of the relevant parameters, shown with default settings:
[in SYSTEM]
ignore-lineup = no
[in SDSL/{ any-shelf any-slot 0 }]
ignore-lineup = system-defined
[in DS3-ATM/{ any-shelf any-slot 0 }]
ignore-lineup = system-defined
ra-upshift-margin-
up
Not currently supported. Specifies the upstream noise margin
relative to 0dB. If the noise level remains at this value for more
than the specified time interval, the line increases its upstream bit
rate.The valid range is 1dB through 31dB.
ra-upshift-int-up
Not currently supported. Specifies the number of seconds (1
through 255) the upshift noise margin can be maintained before
the line increases its upstream bit rate.
ra-upshift-margin-
down
Not currently supported. Specifies the downstream noise margin
relative to 0dB. If the noise level remains at this value for more
than the specified time interval, the line increases its downstream
bit rate. The valid range is 1dB through 31dB.
ra-upshift-int-
down
Not currently supported. Specifies the number of seconds (1
through 255) the upshift noise margin can be maintained before
the line increases its downstream bit rate.
Parameter
Description