Troubleshooting
LED Activity
B-4
WaveLAN/EC-S User’s Guide
When you power-up the WaveLAN/EC-S device, its Power/Error
LED will blink very briefly to indicate start-up diagnostics.
If the error light stays on, this may indicate either a hardware or
configuration error. To determine if it’s a hardware or configuration
error, connect the WaveLAN/EC-S as described in Chapter 3 or
Chapter 4.
■
If you manage to establish a connection to the device, the error
is probably a configuration error that may not prevent the
device from operating.
Display either the Device Info (described on page 3-21) or the
Event Log (described on page 4-48) to determine the nature of
the error and correct it.
■
If you do not manage to establish a connection to the device,
the error may be a configuration error, which prevents you from
accessing the device (like for example an incorrect IP Address)
Use one of the following options to remedy the problem:
— Disconnect power from the WaveLAN/EC-S device and
reconnect it again.
If configuration parameters were changed, without
resetting the WaveLAN/EC-S device, it might still operate
with older configuration parameters preventing you form
accessing the device. Using the disconnect/reconnect
power option will allow the unit to load the correct
configuration from its FlashROM and start operation with
the correct settings.
— Follow the instructions described on page B-5 to reset the
device to its factor-set defaults and proceed as described
in Chapter 3 or Chapter 4.
■
If there is no LED activity at all, verify if the power supply is
properly connected to both power outlet and WaveLAN/EC-S
device.