4-29
Parameter Name Valid Values
■
line length
Any digit in the range of 1 through 1408
(default =1408)
This parameter determines the maximum number
1
of
characters that the WaveLAN/EC-S should wait
before transmitting the data over the radio.
To avoid losing data packets, the number you select
should preferably not be too small.
■
input timeout
Any digit in the range of 1 through 65536
(default =10).
This parameter controls the time period the
WaveLAN/EC-S device should wait and listen for
more data, once a small data stream was received on
the RS-232 port.
The actual time period is related to the Baud rate
selected in the section “Hardware Parameters” on
page 4-27.
For example, if you set the “Baud Rate” is set to 9600,
and this “input timeout” to 10, this means the
WaveLAN/EC-S device can receive up to 960
characters per second.
To allow proper communication, the WaveLAN/EC-S
will wait 1/96th of a second to determine if the host
device wishes to send more data:
■
If another character is received before the time-out
expires, it will restart the timer to wait for more data.
■
If the timer expires, the data is considered to be
complete and will be transmitted immediately.
■
delimiters
One of the Hexadecimal values listed below:
■
0xa (=default)
■
0x8 (rxbd / txbd count)
■