background image

1.00”

(25mm)

SSL-RM

: Remodel collar for installing fixture into drywall / plasterboard.

SSL-CC

: Cavity collar for installing fixture into cavity or bore.

SSL-SC3: Stud-mount collar, adjusts from 1/2” to 3”. Features 1/2” knockouts.

SSL-SC6: Stud-mount collar, adjusts from 3” to 6”. Features 1/2” knockouts.

3. MOUNTING COLLARS - DRY / DAMP LOCATIONS ONLY

SSL-RM

SSL-CC

0.69”(18mm)

SSL-SC3

SSL-SC6

Insert collar into cutout flush with 

finished  substrate;  fold  tabs  over 

to secure

Insert  collar  into  cutout  flush 

with finished substrate; secure 

with customer furnished screws 

or nails or suitable bonding 

adhesive.

2.40” (62mm) 

square cutout

Extend collar 

to be flush 

with finished 

substrate 

Secure collar to 

stud with customer 

furnished screws

SSL1 & ISL1: 2.40” (62mm) 

square cutout

ISL2: 2.40” (62mm) H X 

4.10” (104mm) W cutout

SSL1 & ISL1: 2.40” (62mm) 

square cutout

ISL2: 2.40” (62mm) H X 

4.10” (104mm) W cutout

5

Summary of Contents for ISL1

Page 1: ...ly CAUTION Motors Powertools Extensioncords Appliancesorsimilarelectronics A Fixtures to be mounted in conditions where ambienttemperaturesdonotexceed40 C Ensure AC input voltage is protected against...

Page 2: ...mestic version features 1 2 knockouts Class 2 power supply and multiple driver options Domestic version features 1 2 knockouts Universal back box with 1 2 knockouts wet and concrete pour rated Dimmabl...

Page 3: ...gral power supply universal back box or Bollard feature mounting for 1 fixture Universal back box power supply can support multiple fixtures Separate mounting components required for each fixtures 2 I...

Page 4: ...BB Includes back box gasket and SSL UMP mounting plate features 1 2 knockouts on top bottom and back of box SSL BB Collar Length Includes back box gasket and mounting plate with specified collar lengt...

Page 5: ...SSL RM SSL CC 0 69 18mm SSL SC3 SSL SC6 Insert collar into cutout flush with finished substrate fold tabs over to secure Insert collar into cutout flush with finished substrate secure with customer fu...

Page 6: ...e power supply supplied with hanger bars or brackets specified on order SSL1 ISL1 mount horizontally or vertically ISL2 mounts horizontally only SSL1 ISL1 2 40 62mm square cutout ISL2 2 40 62mm H X 4...

Page 7: ...bolts for concrete pour mounting Concrete Pour Secure bollard to base with supplied screws 4 00 102mm Freestanding mount receives luminaire for flush installation available with integral or remote pow...

Page 8: ...e location in either home run or parallel method Home Run Parallel Back boxes used as example of mounting location At each mounting location connect low voltage wiring to factory supplied 6 lead wire...

Page 9: ...d or Surface Mount Box Push wires into cavity junction box and insert fixture as shown below applying even pressure to face of fixture Note If mounting device collar is not flush with substrate spring...

Page 10: ...veraging the fixture if necessary Disconnect pin connector and remove gasket Gasket Remove 3 hex screws and separate LED assembly from fixture Replace with OEM LED assembly sourced through Lucifer Lig...

Page 11: ...assembly STEP 6 Disconnect additional load wiring if applicable STEP 7 Reattach structure wiring to new driver as applies STEP 8 Install driver assembly note that it must be seated on the rear stud an...

Page 12: ...ply retaining clamps screws nuts as apply STEP 4 Remove and replace driver assembly Fig 5 STEP 5 Secure with retaining clamps screws nuts STEP 6 Reattach lines mains load and control wiring with suita...

Page 13: ...le Purple Ground Hot Black Neutral White To EcoSystem Digital Link Or DALI Digital Bus Black Red LED Light Engine Wiring Supplied by Others AT2 0 10 Volt Driver Lucifer Lighting Power Supply Purple Pu...

Page 14: ...ny repairs or modifications other than those made by the Seller This Warranty does not cover damage or failure caused by abnormal spikes in power dirty power and light fixtures used with power supplie...

Reviews: