background image

3

Bedienungsanleitung - Nano Clean / Mini Pump

Operating Conditions

•  The device may only be operated at 230-240V / 50/60 HZ AC Voltage.
•  The allowed water temperature may not fall below +1° or exceed 35°C during 

operation.

•  Outdoor use is not allowed.
•  The pump/filter must be submerged all the time for proper function.

Designated Use

Nano Clean / Mini Pump may only be used in freshwater without any additives. 

Another use as prescribed is not allowed!

Operation Mini Pump

The pump is turned on by connecting the plug to the wall socket. The flow rate 

is not adjustable. 
•  Attach the hose (ø 13 mm) to the pump outlet
•  Attach the pump with suction cups to the floor of the Aqua-Tarrium or aqua-

rium

•  Make sure the pump is fully submerged
•  Lead the cable of pump through the hole in the top of the waterfall and 

through a cable lead through in the lid.

•  -Connect the pump to the wall socket

Operation Nano Clean

Das Einschalten erfolgt über den Anschluss an die Netzspannung. Die Fördermen-

ge ist nicht regulierbar. 
•  Attach the hose (ø 13 mm) to the pump outlet
•  Attach the pump with suction cups to the floor of the Aqua-Tarrium or aqua-

rium

•  Make sure the pump is fully submerged
•  Lead the cable of pump through the hole in the top of the waterfall and 

through a cable lead through in the lid.

•  Connect the pump to the wall socket

Cleaning and Servicing

For flawless operation pump case and rotor have to cleaned regularly. Dirt can 

cause dysfunction and reduce the pump performance.
Attention: unplug the pump before doing any servicing or cleaning!
For cleaning remove the grill and pull out the rotor. Clean the parts with a soft 

brush. In case of lime stains  the parts can be cleaned in vinegar. The motor itself 

does not need servicing.
For cleaning the filter part of the Nano Clean remove the filter chamber. Rinse 

the sponge under water until clean. After removing the filter chamber you do 

also have access to the pump head and can clean it. Remove the cover to get 

to the impeller.

Safety Instructions

•  Always disconnect all electrical appliances from the mains before placing your 

hands in to the water!

•  It‘s not allowed to use the pump in swimming pools or bathrooms.  
•  The power plugs of both devices cannot be replaced in case of damaging, in 

this case, the complete device has to be replaced.

•  Do not operate the devices at temperatures in the freezing range.
•  The water temperature may not exceed 35°C.
•  Do not add unsuitable or low-grade additives to the water
•  The pump/filter is only allowed for use in water. Never operate the pump in 

flammable liquid. 

•  Do not use chemical additives for cleaning the pump.
•  Do not make modifications to the device, and do not open the case!

Disposal

In accordance with RL 2002/96/EG the product must not be added 

to the normal household waste. It must be disposed of property.  

Warranty

The warranty expires in case of modification and repair attempts as well as da-

maging by force or inappropriate usage.
Neither a guarantee nor any liabilities for detriments or consequential damages 

in relation with this product will be assumed. Repair, amendments or exchange 

for a replacement are at the manufacturer’s discretion.

Technical Data Mini Pump

Operating voltage:  

230-240VAC ~ 50/60Hz

Wattage of pump:  

4,4 W 

Delivery rate of the pump: max.  

350 l/h

Max. delivery height: 

 0,62 m

Dimension:  

54x43x62 [mm]

Hose connector:  

Ø 13 mm

Technical Data Nano Clean

Operating voltage:  

220-240VAC ~ 50/60Hz

Wattage of pump:  

1,7 W 

Delivery rate of the pump: max.  

210 l/h

Max. delivery height:  

0,4 m

Dimensions:  

54x43x62 mm

Hose connection  

Ø 13 mm

Manual - Nano Clean / Mini Pump

GB

Summary of Contents for Nano Clean

Page 1: ...Bedienungsanleitung Operating Instructions Nano Clean Mini Pump...

Page 2: ...Filterschwamm unter flie endem Wasser Nach Abziehen der Filterkammer haben Sie auch freien Zugang zur Pumpeneinheit des Nano Clean und k nnen diese reinigen Ziehen Sie die Abdeckung ab um an den Roto...

Page 3: ...vicing For cleaning the filter part of the Nano Clean remove the filter chamber Rinse the sponge under water until clean After removing the filter chamber you do also have access to the pump head and...

Page 4: ...r nettoyer le filtre de la Nano Clean tirer la chambre de filtre vers le bas et rincer l ponge sous l eau courante Apr s avoir enlev la chambre de filtrati on vous avez acc s la pompe et pouvez la net...

Page 5: ...ng n mantenimiento ParalimpiarelfiltrodelNanoCleantirardelac maradelfiltroalabajayaclare la esponja con agua corriente Despu s de quitar la c mara del filtro tambi n tienen libre acceso a la unidad de...

Page 6: ...Mini Pump Mini Pump 13 Aqua Tarrium Nano Clean Nano Clean 35 RL 2002 96 EG Mini Pump 230 240VAC 50 60Hz 4 4 W 350 l h 0 62 m 54x43x62 mm 13 mm Nano Clean 220 240VAC 50 60Hz 1 7 W 210 l h 0 4 m 54x43x...

Page 7: ...e azijn worden gelegd De motor zelf is onderhoudsvrij Verwijder de filterkamer de Nano Clean voor reiniging en spoel de spons onder water Na het verwijderen van der filterkamer je hebt toegang tot de...

Page 8: ...he libero accesso alla pompa e il Nano Clean si pu rimuovere Togliere il coperchio per arrivare al rotore Avvertenze di sicurezza Prima di immergere le mani in acqua scollegare tutti gli apparecchi el...

Reviews: