Display & MIN /MAX Function:
The display always shows the current temperature. If a red lamp is lighting above WORK the device is on. If a lamp is lighting above SET the device
is in settings mode.
With the arrow key up you can display the maximum measured temperature, with arrow key down the minimum measured temperature. The values
are reset every day at 00:01.
ENT will show the actual time. SET will show the currently valid temperature setting. All other settings can only be viewed in settings mode.
Important Information:
• If the temperature range (0°-50° C) is exceeded the display will show HHH for a higher and LLL for a lower temperature and an alarm will sound.
• In case of sensor error an alarm will sound and the display will show EEE. Contact your dealer.
• The device saves settings in case of power loss for about 48 hours.
• Do not undertake any modification and do not open the case.
• Device and sensor cords have to be checked always for signs of damage. If a defect is discovered the device has to be put out of operation immedi-
ately. The same applies if the device has come into contact with fluids.
• Generally it should be verified if the device is applicable for the application at hand before putting it into operation!
• In case of doubt consultation of experts or the manufacturer of the employed devices is required.
• In order to avoid animal losses regular checks of the temperature are required. Claims for losses due to malfunction of the controller cannot be
accepted.
• Do not use light bulbs (incandescent spot lamps) with a thermostat. Since the thermostat often turns the lamps on and off, their live time is signifi-
cantly reduced and it causes a lot of stress for the animals.
Warranty
The warranty expires in case of modification and repair attempts as well as damaging by force or inappropriate usage.
A manufacturer warranty of 2 years is granted on this device. Repair, amendments or exchange for a replacement are at the manufacturer’s discretion.
Neither a guarantee nor any liabilities for detriments or consequential damages in relation with this product will be assumed.
In case of warranty claims or repairs contact your specialist dealer.
Technische Daten
Voltage:
230 V~ 50/60 Hz
Maximum Load:
1000W
Power Consumption:
< 1,5W
Temperature Setting:
0° bis 50°C
Temperature Range:
0° bis 50°C
Accuracy:
+- 1°C
Resolution:
0,1°C
Temp. Difference for Switching:
0,5 - 15°C
Alarm when exceeding temp:
+- 0° bis 15°C
3.