background image

7

F

0

3

7

F

CLR

ENT

ENT

ENT

ENT

ENT

ENT

ENT

ENT

ENT

ENT

ENT

ENT

ENT

ENT

ENT

4. Results

Coupling Results

• Press 

 until  

  appears. Press 

 or

  or 

  to  toggle  through  offset  and

angular misalignment.

(+) Positive coupling offset

p

(-) Negative coupling offset

q

(+) Positive coupling gap
(-) Negative coupling gap

Repeat sections 3 and 4 to establish repeatability.

Foot Corrections

• Press 

 until  

 appears. Press 

 or

  or 

  to  toggle  through  vertical

shimming and horizontal move corrections.

Arrows show direction of move or shimming. Apply
correction to blinking feet.

2. Enter dimensions

•

1. Laser to prism

(Arrow point to hash mark "

f

" on prism)

(Center-to-center of support posts)

•

2. Laser to center of coupling

(Center of flex planes)
Note: See F73 if you have a spacer coupling.

•

3. Working diameter

10"

(Coupling diameter)

(Default  value)

•

4. RPM

•

5. Laser to front foot

•

6. Front foot to back foot

1. Mount OPTALIGN

®

 PLUS

and switch on

Stationary

Machine

MTBM

(Machine To

Be Moved)

3. Measure

• Adjust prism so that laser beam strikes center

of the prism cap cross hair.

• Remove cap.
• Adjust  prism  until  coordinates  are  close

to 

00

.

•

will appear on the screen.

• Rotate shafts at least 75°.

5. Move

• Choose  position  (45°,135°,225°,315°)  by

rotating shaft until desired angle appears (±4°).

• Select direction of Move (horizontal or vertical)

using 

. Confirm with 

.

• Adjust beam to 

00

 if necessary.

• When

appears press 

.

• Move machine into alignment.

Resume

: You can resume where you last left off

by pressing 

  

.

Soft Foot

• Position shafts at either 90° or 270° (±4°).
• Adjust  beam  close  to 

00

  if  necessary.

Press 

. (Not necessary if "

----

" appears.)

• Press 

 then loosen the bolt, press 

to record value then tighten bolt.

• Press 

 or 

 to move to the next foot.

Follow  this  procedure  for  all  remaining  feet  and
correct soft foot if greater than 0.002".

Static Feet

• Press 

 

 

.

appears.

• Select desired static feet (flashing) with 

or 

. Press 

 . Enter missing dimen-

sions when prompted.

Coupling Type

• Press 

 

 

 or 

appears.

• Select desired type with 

. Press 

.

If

is selected, enter spacer length when

prompted.

CLR

CLR

CLR

F

F

F

F

7

F

7

7

7

(Note: Add 2” if using the Beam Deflector.)

Reviews:

Related manuals for OPTALIGN PLUS