background image

2

F

8

F

0

0

6

F

6

F

ENT

ENT

ENT

ENT

ENT

ENT

InfiniRange

®

 

(Measurement Range Extension)

Using InfiniRange while in Measure:

• If

or

appear  during  rotation,

turn  shafts  back  at  least  5°  until  numbers
reappear, then pause. 

InfiniRange

 then starts

automatically. (

, shows...)

• When  

  appears readjust beam to 

00

.

• When

appears press 

.

• Proceed with measurement.

Note: Initiate 

InfiniRange

 manually any time provided

coordinates are displayed, with  

 

 .

Using InfiniRange while in Move:

• If

or

appear  during  Move,

move machine back until numbers reappear.

• Press 

 

 and wait for 

InfiniRange

 to

start.

• When  

  appears readjust beam to 

00

.

• When

appears press 

.

• Continue moving machine.

OPTALIGN

®

 PLUS

Quick Reference

Vertical Machines 

(see manual)

600

5.0

9.0

10.0

15.0

1.8

3.0

900

3.0

6.0

7.0

10.0

1.2

2.0

1200

2.5

4.0

5.0

8.0

0.9

1.5

1800

2.0

3.0

3.0

5.0

0.6

1.0

3600

1.0

1.5

2.0

3.0

0.3

0.5

7200

0.5

1.0

1.0

2.0

0.2

0.3

TolChek

®

 — Display

always lit: Value within Excellent tolerances

 flashes: Value within Acceptable tolerances

No ‘smiley’: Out of tolerance

TolChek

®

 

— Report

O K

= Excellent

A C

= Acceptable

- -

= Out of tolerance

All Speeds: Maximum Soft Foot Reading 2 mils.

Use OEM or in-house tolerances if available.

Tolerances for Shaft Alignment

Offset

(mils)

Excellent Acceptable

RPM

Gap

(mils/10")

Excellent

Acceptable

Spacer Shaft

(mils/inch)

Excellent Acceptable

Targets

• Press 

 until 

 appears. Press 

to  confirm  coupling  diameter  (change  if
necessary).

• Enter  coupling  targets  in  inches  in  the

following order VO, VA, HO and HA.  Press

 after each entry.

Thermal Growth

• Press 

 (twice) until 

 appears.

• Enter thermal growth values in inches at the

feet. Press 

 after each entry.

Note: Use the F70 function to enter growth values for
the left machine.

©2001 LUDECA, INC.

Optalign, InfiniRange, Tolchek are registered trademarks of Prueftechnik AG.

Measurement Averaging

• Press 

.

• Select from 2 to 7 and confirm with 

.

Storing, Printing and Data Transfer

Saves file

Opens file

Prints a report

Transfers data from the PLUS to

a PC using the Optalign Plus PC

Commander software.

Order No. 01-597-01 

Rev. 

v

Your local contact —Norm Voelzow

V

oelzow & Company, Inc.

P.O. Box 0158 • Wingate, NC  28174

Phone 704-233-9222  •  Fax 704-233-9211

E-Mail: voelzow@perigee.net

LUDECA, Inc.

1425 N.W. 88th Avenue, Miami, FL  33172
Phone: (305) 591-8935  •  Fax (305) 591-1537
info@ludeca.com • www.ludeca.com

4

2.

Version 2.0x

Reviews:

Related manuals for OPTALIGN PLUS