background image

2. Mark out four 90

˚

 positions (1, 3, 5, 7) as shown

(or if shaft rotation is limited, eight 45

˚

 pos'ns, 1,

2, 3, 4,…8).

3. Enter dimensions:

CIRCLE/SQUARE (select bolt pattern)
NUMBER BOLTS (square must be 4, 8, 12…)
OPTION allows non-symmetrical flange
(NORMAL ORDER clears and resumes
symmetrical)
• Bolt Distance (diagonal diameter of bolts)
• Flange Diameter (diagonal diameter of flange)
• Coupling center to receiver

4.           Turn shaft to position 1, align laser and

press '1.' Turn to each position and press
corresponding key. At least 3 positions are
required.

5.           Table shows either all shim corrections

added (+), removed (-) or for minimum movement
(+/-). Select with '+/-' key.

6.             Turn to position '1' and press             .

Shim as per table. Press

7. Re-measure, view results and move horizontally

if vertical is in tolerance.

MENU

Main Menu

Vertical Machines

1. Mount ROTALIGN

Laser

on lower
machine

START

STOP

MOVE

MACHINE
SETUP

COUPLING
TYPE

MEASURE
MODE

SOFTFOOT

COUPLING
TARGET

THERMAL
GROWTH

TOLER-
ANCES

STATIC
FEET

Select machine types: 'normal 4-feet,'
'6-feet,' 'single bearing,'  'V-form.'  Left
machine can be made moveable.

Select  'short flex,'  'single plane' (solid)  or
'spacer shaft.' CHANGE MODE selects
the display mode for coupling
misalignment values.

Select 'Continuous sweep' (the default),
'Measure at 0, 3, 6, 9,'   'Multipoint'  or
'Pass mode' (for uncoupled shafts).

Select foot softkey & loosen bolt. Value

appears–press STOP and retighten. Results

must be carefully analyzed to determine
the correct shimming—see manual.

Enter the 'cold' coupling target alignment,
based on display mode selected in
COUPLING TYPE above.

Enter the expected horizontal and vertical

movement for the feet.

TABLE tolerances based on RPM. Press
EDIT and enter RPM.  The Smiley face
will then appear in the results screen.
Select TABLE TYPE:  'excellent,'

'acceptable' or 'user-defined.' '50Hz/60Hz'
shows different sets of RPM increments.

Set feet which cannot be moved. If left
machine  is  'Stationary '  (in MACHINE
SETUP above) then entire right machine
must be moveable.

CONFIGURATION
USER SETUP
FILE
REPORT
PC-COMM

PRINTER CONFIG.
RS232 CONFIG.
CHANGE APPLIC.

Unit, Language, Contrast, Date.
Enter user name, company etc.
Save, Open files, etc.
Print selected file.
Communicate with PC using
'ROTALIGN Commander' software.
Select your printer from a list.
Configure the serial (COM) port.
Change to Vertical or Horizontal
machine, or 

Quick Check.

Reset:
In case of 'lock-up' press

ON

OFF

ENTER

CLR

all at
once.

To select inch/mm:

EDIT

OK

MENU

© 2005 Printed in Wingate, NC 2005 rev. 4

ROTALIGN

®

Short Instructions

Norm & Bev Voelzow

— US Distributor —

LUDECA, Inc.

1425 N.W. 88th Avenue, Miami, FL  33172
Phone: 305-591-8935  •  Fax: 305-591-1537

Web:

 http://www.ludeca.com/

E-Mail:

 webmail@ludeca.com

V

oelzow & Company, Inc.

 • Wingate, NC  28174

704-233-9222  •  Fax  704-233-9211

E-mail: nvoelzow@perigee.net

Web: www.LaserAlignment.net

4804 Lawyers Rd E