13
Procedure:
1. Fully pull the unlocking button and carefully pull the battery upwards out of the de
-
vice.
Do not use force!
2. The battery can now be recharged in the charger (please take note of the separate
operating instructions for the charger and the batteries to be used).
3. Insert the recharged or new battery into the eDRAULIC device until it reaches the
stop. The battery will be automatically locked when correctly operated.
Opening the device:
Turn the star grip in a clockwise direction (in the direction of the
relevant symbol) and keep in this position.
Closing the device:
Turn the star grip in an counterclockwise direction (in the direction
of the relevant symbol) and keep in this position.
"Dead-man’s" function:
Following release, the star grip automatically returns to the
central position, fully guaranteeing load retention.
5.2 Operating the star grip
(also see chapter on "Operating movement control")
Connection slot