The device is filled with a 

hydraulic fluid. These hydraulic 

fluids can be harmful to your 

health if swallowed or if their 

vapours are inhaled. Direct 

contact with the skin should 

be avoided for the same 

reason. Please also note that 

hydraulic fluids can also have 

an adverse effect on biological 

systems.

When working with or storing 

the equipment, ensure that the 

function and the safety of the 

equipment are not impaired by 

the effects of extreme external 

temperatures and that the 

equipment is not damaged in 

any way. Please note that the 

device can also heat up over a 

long period of use.

In the event of malfunctions, 

immediately deactivate the 

device and secure it. You 

should have the malfunction 

repaired immediately.

Do not carry out any changes 

(additions or conversions) to 

the device without obtaining 

the prior approval of LUKAS.

Observe all safety and danger 

notices on the device and in 

the operating instructions.

All safety and danger notices 

on the device must be kept 

complete and in a legible 

condition.

Any mode of operation which 

impairs safety and/or stability 

of the device is forbidden!

Comply with all stipulated 

dates or dates specified in 

the operating instructions 

pertaining to regular tests / 

inspections on the equipment.

Safety devices must never be 

disabled!

The maximum permitted 

operating pressure noted on 

the equipment must not be 

exceeded.

Before the device is switched 

on / started up, and during its 

operation, it must be ensured 

that nobody is endangered by 

the operation of the device.

Only original LUKAS 

accessories and spare parts 

may be used for repairs.
Please ensure that, when 

working with this equipment 

or during transportation of 

such, you do not become 

entangled in the looped hoses 

and trip.

When working in the proximity 

of live components and wires, 

appropriate steps must be 

taken to avoid current flow 

or high-voltage discharge 

through the device.

The build-up of static 

charge with the potential 

consequence of spark 

formation is to be avoided 

when handling the device.

Summary of Contents for HP 25/ T700R

Page 1: ...Operating Instructions Re railing Technology 84072376585 GB HP Cylinders Translation of the original operating instructions Edition 12 2011...

Page 2: ...2...

Page 3: ...2 Commissioning 14 7 3 Hydraulic cylinder control 15 8 Use of accessories 16 8 1 Base plate 16 8 2 Multistage sets 16 9 Dismantling the device deactivation following operation 20 9 1 Hydraulic cylinde...

Page 4: ...and the possible consequences 1 Hazard classes Pictogram Damage injury to Key word Definition Consequences human DANGER Immediate danger Death or major injury WARNING Potentially dangerous situation...

Page 5: ...hoses the accessories and the connected hydraulic equipment must also be observed Even if you have already received instructions on how to use the equipment you should still read the following safety...

Page 6: ...ating instructions All safety and danger notices on the device must be kept complete and in a legible condition Any mode of operation which impairs safety and or stability of the device is forbidden C...

Page 7: ...facturer supplier is not liable for any damages resulting from improper use The user bears sole responsibility for such Observance of the operating instructions and compliance with the inspection and...

Page 8: ...vehicle in order to push a towing device underneath it for example HP cylinders in telescopic design offer long hoisting paths with a low retracted overall height The accessories necessary for the pa...

Page 9: ...onal cases Securing against unwanted lowering of the cylinders in the event of a hose breakage is achieved by means of quick stop couplings fitted to the hose If there is any doubt as to which couplin...

Page 10: ...of LUKAS Ensure in particular that the maximum permissible operating pressure for the connected LUKAS equipment is not exceeded NOTE Before you use pumps from a different manufacturer you must contact...

Page 11: ...der Hoses can be connected only when depressurised For dust protection the supplied dust protection caps must be refitted 6 2 Coupling quick disconnect couplings The equipment is connected to the hydr...

Page 12: ...TENTION Hydraulic fluids may produce a lubricating film on the ground CAUTION ATTENTION When using wooden underplates care must be taken that particularly hard wood without damage is used so that the...

Page 13: ...g staff or the cylinder itself The load should always contact the middle of the piston area Side loads should be avoided WRONG RIGHT Load Load WRONG RIGHT Load Load It is usually not possible to make...

Page 14: ...all cylinders WRONG RIGHT WARNING CAUTION ATTENTION Always keep a sufficient distance away from the hydraulic cylinder when pressurising it in particular when commissioning the equipment after instal...

Page 15: ...inder piston cannot be directly controlled by the cylinder Extending and retracting the cylinder must be controlled via a separate control unit or the connected hydraulic unit 7 2 1 Initial operation...

Page 16: ...cylinders To find out which multistage set is suitable for your cylinder please contact your authorised dealer or LUKAS directly 8 Use of accessories 8 1 Base plate Base plates are provided to Increas...

Page 17: ...C 3 Lower the load onto this cylinder attachment and retract the piston 4 Remove the standard piston guard plate from the cylinder if present 5 Insert first piston attachment D with neck in piston cen...

Page 18: ...his cylinder attachment WARNING CAUTION underneath the load Operation Schematic E A C D 9 Insert second piston attachment F with neck into centring device of the first attachment use fork lever 10 Com...

Page 19: ...and piston attachments have been mounted WARNING CAUTION underneath the load WARNING CAUTION ATTENTION Never use several multistage sets at the same time on one HP cylinder as otherwise stability cann...

Page 20: ...nical strain on the device NOTE When hydraulic cylinders are in storage fluctuations in ambient temperature can cause the pistons to move slightly This phenomenon is due to the difference in the expan...

Page 21: ...ry out maintenance and repair work tools appropriate for the job and personal protective equipment are essential Inspections to be carried out Visual inspection Cylinder and piston rod undamaged and n...

Page 22: ...those components in the replacement parts lists for the relevant unit may be replaced Other components on the cylinders may only be exchanged if You have taken part in appropriate LUKAS service traini...

Page 23: ...ent temperatures change substantially When selecting a suitable hydraulic fluid please refer to chapter Hydraulic fluid recommendations Procedure 1 Completely retract the cylinder 2 Dismantle the valv...

Page 24: ...ing replacement parts list for the cylinder Procedure 1 Remove the coupling 2 Position the new coupling and tighten it to the torque stated in the corresponding replacement parts list for the cylinder...

Page 25: ...apply the specified force Hydraulic fluid level in the supplying pump Insufficient hydraulic fluid in the pump Top up hydraulic fluid deaerate Check operating pressure of driving hydraulic unit Press...

Page 26: ...the part to be lifted thereby suddenly increasing the load Secure the load and move using other tools Apply the cylinder at a different point where the load to be moved is lighter Use supporting equip...

Page 27: ...013 Erlangen Phone 49 09131 698 348 Fax 49 09131 698 353 13 Technical Data NOTE The following tables contain only the most important Technical Data Further information about your device is available d...

Page 28: ...6 133 146 133 Compression force piston 3 kN 650 lbf 146 133 max stroke piston 1 mm 90 90 223 in 3 54 3 54 8 78 max stroke piston 2 mm 95 95 228 in 3 74 3 74 8 98 max stroke piston 3 mm 94 in 3 70 Tota...

Page 29: ...39 658 374 326 374 326 max stroke piston 1 mm 89 195 198 253 in 3 50 7 68 7 80 9 96 max stroke piston 2 mm 96 205 200 250 in 3 78 8 07 7 87 9 84 Total piston stroke mm 185 400 398 503 in 7 28 15 75 15...

Page 30: ...15 Bio oil Oil temperature range Oil code Viscosity rating Remarks A 11 2 86 F HL 5 VG 5 B 0 4 122 F HM 10 VG 10 C 17 6 167 F HM 22 VG 22 D 41 0 176 F HM 32 VG 32 E 17 6 158 F HF E15 VG 15 Bio oil rec...

Page 31: ...31 14 EC Declaration of Conformity...

Page 32: ...Phone 49 0 91 31 698 0 Fax 49 0 91 31 698 394 e mail lukas info idexcorp com www lukas com Made in GERMANY Copyright 2011 LUKAS Hydraulik GmbH HP_Zylinder_BA_GB_84072376585_1211 indd Subject to revisi...

Reviews: