11
4.5 Hydraulic supply
4.6 Hoses
Only LUKAS hand pumps may be used to drive the equipment.
If the hand pump is a different make, you must make sure that it complies with LUKAS
specifications, otherwise potential dangers may occur, for which LUKAS cannot be held
responsible. Ensure in particular that the authorised operating pressure for LUKAS
equipment is not exceeded.
NOTE:
Before using pumps from a different manufacturer, you must contact LUKAS or
an authorised dealer.
The hand pump and door opener are connected by hose lines.
ATTENTION!
The HT90 and HT99 door openers may only be operated with mineral oil in
accordance with section 11.1 “Recommended hydraulic fluids”.
The Jack Rabbit Tool JL-8 may only be operated with mineral oil in accordance
with section 11.1 “Recommended hydraulic fluids”.
5.
Connecting the equipment
5.1 General information
A female screwed coupling is mounted on the device; it is connected to the hand pump via a
hose. The hose is equipped with couplings so that it can be connected without error.
5.1.1. Door opener HT90
5.1.2. Door opener HT99
WARNING / CAUTION / ATTENTION!
Prior to connecting the devices, ensure that
all the components
being used
are suitable for the
maximum operating pressure
of the pump unit
. In case of doubt, you
must
contact LUKAS
directly
.
A (Flat-Face) female quick-disconnect coupling is mounted on the device; it is connected to
the hand pump via a hose. The hose is equipped with couplings so that it can be connected
without error.