User’s Manual ... 11
12/24/36/48/
1/2/4/6Hr
Set cut-off at input voltage under 11.8V
in 12/24/36/48/1/2/4/6 hours
c 24.0
12Hr
rEs
Display
Display standard cut-off setting at 12V
Display cut-off setting 12 hrs after
standard cut-off setting
Operation Contents
Cut-off voltage: 12V / Timer: 12 hours
Slide S/W
Volt Mode
Select
VoLt
Mode
HoUr Mode
Set cut-off at input voltage of 24.1V
Set cut-off at input voltage of 24.2V
Set cut-off at input voltage of 24.3V
Set cut-off at input voltage of 24.4V
Set cut-off at input voltage of 24.5V
Set cut-off at input voltage of 24.6V
Set cut-off at input voltage of 24.7V
Set cut-off at input voltage of 24.8V
Set cut-off at input voltage of 23.2V
Set cut-off at input voltage of 23.3V
Set cut-off at input voltage of 23.4V
Set cut-off at input voltage of 23.5V
Set cut-off at input voltage of 23.6V
Set cut-off at input voltage of 23.7V
Set cut-off at input voltage of 23.8V
Set cut-off at input voltage of 23.9V
c 24.1
c 24.2
c 24.3
c 24.4
c 24.5
c 24.6
c 24.7
c 24.8
c 23.2
c 23.3
c 23.4
c 23.5
c 23.6
c 23.7
c 23.8
c 23.9
KEY
Slide S/W
Volt Mode
Enter
Display Output Voltage
Display Input Voltage
Display Voltage
Display Voltage
Mode
※ Voltage setting at less than 11.8V is not recommended.