WARNING / BEWARE!
The LX-Strut is inserted through the ratchet when used correctly with
a max. pre-load force of 0,05 to.
.
This results in a safety factor of 9
when the prop is fully extended.
max. Preload force
0.05 to.
max. Load bearing
capacity
2,10 tons.
max. Load bearing
capacity
0.50 to.
5. Allowable stresses
10-fold safety
on preload force
F1
F2
1.5-fold safety
on breaking load
30
LUKAS Operating Instructions LX-Strut