4.4
Operating movement controls
The piston movement is controlled by the star grip on the attached valve (see illustration
below). The symbols show the turning direction for opening and closing the tool tips.
Star grip
5.1
Battery for StrongArm™ e100/le100
5.
Operation
Commissioning
Before initial operation, the battery of the rescue device must be fully loaded, using the
external charger.
Procedure:
1.
Fully press back the red release button and
pull the battery carefully out of the battery
cradle.
Do not use force!
2. The battery can now be recharged in the
battery charger and replaced again
(observe also the separate instruction
manual for the battery charger).
3. Insert the recharged or new battery into
the cradle so that the red release button
automatically engages. Thus, the battery is
locked again.
Battery cradle
1
2