27
e100_le100_manual_173100085_EN
07/2017
Attachment screws
(torx TX 15)
Filter cover
Filter element
The air suction filter is to be checked at least once a year or after use in a dusty environment.
The filter can be checked from the outside if the battery is removed (see illustrations below).
If the filter is severely contaminated, it will need to be replaced.
The removable filter cover is located on the outside at the rear housing where it is fixed with
two screws.
Procedure:
1. Unscrew the two attachment screws at the cover with a torx wrench/screwdriver (TX 15)
and take the cover off (see illustration below).
2. Now you can take out the filter element and replace it by a new one.
3. Reassembling will be carried in reverse order.
Do not exceed the
torque of 1.5 Nm (13 lbf·in.)
, to avoid damaging the thread or housing.
9.4
Checking and exchanging the filter element
Filter element