background image

Lumacell

Tel: (888) 552-6467 ext. 547 or 255

Fax: (888) 867-1565

www.lumacell.com

06/04 750.1048 Rev. B

1/4

LER3000 Series – Polyvinyl Exit Sign

LER3000 Series – Polyvinyl Exit Sign

AC/DC & Self-Powered Models

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should 
always be followed including the following:

READ AND FOLLOW ALL SAFETY 
INSTRUCTIONS

1. Do not let power supply cords touch hot surfaces.

2. Do not mount near gas or electric heaters.
3. Use caution when handling batteries. Avoid possible shorting.
4. Equipment should be mounted in locations and at heights where it 

will not readily be subjected to tampering by unauthorized personnel.

5. The use of accessory equipment not recommended by the manufac-

turer may cause an unsafe condition.

6. Do not use this equipment for other than intended use.
7. All servicing should be performed by qualified service personnel.

SAVE THESE INSTRUCTIONS

Installation Instructions

1. Turn off unswitched AC power.

Canopy Mount

a. Remove canopy assembly from carton. Remove mounting plate 

from canopy and retain securement screw.

b. Route unswitched AC circuit wires into the junction box and leave 

6” of wire length.

c. Remove proper knockouts in canopy backplate for desired 

mounting position. 
For 

Nexus

 option, install the liquid tight fitting, provided with the 

unit. For Ceiling mount, use the k’out located on side of the unit 
(opposite side of the diagnostic display). For Side mount, use the 
k’out located on top of the unit (see fig. 4).

d. Feed unswitched AC wires through large hole in canopy mount-

ing plate. 

e. Make sure the securement screw is accessible (see fig.1 part # 

13). Use existing screws in junction box to secure canopy back-
plate to the junction box.

f. Remove lens, exit panel and diffuser panel on the front of the unit 

(use the supplied bit to remove the tamper-proof screws).

g. In order to access the knockouts of the frame, remove the 4 elec-

tronic module screw(s) holding the electronic module to the frame 
and separate them (see fig.2).

Figure 1

Part List

1. Tamper-proof screws short 

(4 per lens)

2. Tamper-proof screws long 

(2 per lens)

3. Lens
4. EXIT panel
5. Diffuser panel
6. Frame
7. Electronic module
8. Electronic module screws 

(4)

9. Backplate (single face sign)
10. Backplate tamper-proof 

screws (4)

11. Lock-nuts (2)
12. Gasket washer (2)
13. Canopy securement screw
14. Canopy
15. Nipple assembly (2)
16. Canopy backplate
17. Junction box screws (not 

supplied)

18. Junction box (not supplied)
19. Nylon washer (2 for wall 

mount)

20. Junction box gasket (for 

wall mount)

Figure 2

Summary of Contents for LER3000 Series

Page 1: ...of wire length c Remove proper knockouts in canopy backplate for desired mounting position For Nexus option install the liquid tight fitting provided with the unit For Ceiling mount use the k out located on side of the unit opposite side of the diagnostic display For Side mount use the k out located on top of the unit see fig 4 d Feed unswitched AC wires through large hole in canopy mount ing plat...

Page 2: ... Connect the white lead to neutral and the purple lead to AC line volt age the input is universal 110 to 347 VAC See fig 5 Optional For AC models used with DC remote power the sealed DC nipple wire assembly 2 wires will also need to be installed One end connects to the LED STRIP leads inside the enclosure and the other end to DC input inside the junction box Connect the red lead to positive and th...

Page 3: ...mal operation No fault Service Required is OFF and one of the two internal LED blinks showing that the micro controller is active Faulty operation Service Required blinks Battery Alarm ON Charger Alarm OFF Check battery or replace battery Battery Alarm ON Charger Alarm ON Check LED strip Battery Alarm OFF Charger Alarm ON Check charger circuit Nexus models Nexus models use two local indicators One...

Page 4: ...lready be installed 4 Install the diffuser panel by snapping the top edges under the two top retention screws and then snapping the bottom edges under the two bottom retention screws see fig 11 5 The EXIT panel installs in the same manner if required remove the appropriate chevron 6 Install the lens by using the 4 short and 2 long tamper proof screws see fig 12 The tamper proof screws should be eq...