Section 11 – Command Interface
Radiance 2021 and Radiance 2041
rev 053013
33
Section 11 – Command Interface
Direct Commands
Direct Commands are entered by using the Lumagen remote control or RS232 interface.
See Radiance Tech Tip 13 “Direct Commands and Menu Shortcuts” which contains a complete list
commands. This Tech Tip is available for download at
Output Vertical Resolution
480p:
MENU 0 2 1
Progressive with 480 active scanlines
540p:
MENU 0 2 2
Progressive with 540 active scanlines
720p:
MENU 0 2 4
Progressive with 720 active scanlines
768p:
MENU 0 2 5
Progressive with 768 active scanlines
1080p:
MENU 0 2 7
Progressive with 1080 active scanlines
1080i:
MENU 0 2 8
Interlaced with 1080 active scanlines
Output Mode Commands
Output 2D
MENU 0 3 0
Set output mode to 2D
Output 3D-SBS
MENU 0 3 1
Set output mode to 3D Side-By-Side
Output 3D-TB
MENU 0 3 2
Set output mode to 3D Top-Bottom
Output Vertical Rate
Set vertical rate:
MENU 0 4 (50Hz, 60Hz) OK
Output Aspect Ratio
Output aspect ratio: MENU 0 6
value
OK
Example: For 16:9 enter178
Miscellaneous Commands
Menu timeout
MENU 0 9 0 5
Toggle menu timeout. Short (default) or long (saved)
Service Mode
MENU 0 9 1 0
Toggle SERVICE MODE. (not saved)
Reinterlace Off
MENU 0 9 4 0
Turns reinterlacing off
Reinterlace On
MENU 0 9 4 1
Turns reinterlacing on
Toggle field order
MENU 0 9 4 2
Toggles field order for reinterlacing
Unlock menu
MENU 0 9 1 5
Can also be selected using menu
Output defaults
MENU 0 9 9 8
Reset current output to default for current resolution
Factory defaults
MENU 0 9 9 9
Reset to factory default (Must “Save” to make permanent)
Menu Shortcuts
See Radiance Tech Tip 13 “Direct Commands and Menu Shortcuts” which contains a complete list
commands. This Tech Tip is available for download at
IR Command List
See Radiance Tech Tip 12 “IR Command Interface” which contains a complete list of IR commands.
This Tech Tip is available for download at
ASCII Command List
See Radiance Tech Tip 11 “RS232 Command Interface” which contains a complete list of RS232