71
VENTUS 2.0 Manual / Updated 2013/2/15
/ Operational Manual
VENTUS 2.0
Parade Set Support
- Support to select Parade ID, NoG, TPC PRC, RS Frame Mode, SCCC Block Mode, Primary & Secondary RS Code
Mode, and Select Ensemble.
- Parade ID : 0 ~ 127 specifies the ID of the range. If Parade ID set the same value, Only one can be used as the
RF output at the same time.
- NoG : Number of Group can be selected from Minimum NoG to 8.
- TPC PRC : Some kind of burst mode. Can be selected from 1 to 8.
(Parade is transmitted once every (x) M/H Frame with the data for (x) M/H Frame.)
- RS Frame Mode : “Single Frame (Primary RS Frame use only)” or “Dual Frame (Primary and Secondary RS Frame
with)” can be chosen.
- SCCC Block Mode : ‘Separated Block’ or ‘Paired Block’ can be chosen.
- In the Separated Block Mode, User can choose code rate ½ or ¼ in ‘SCCC Block Region A ~ D’
- In the Paired Block Mode, User can choose code rate ½ or ¼ in ‘SCCC Block Region All’
- RS Code Mode : may choose one from (211,187), (223,187), (235,187) .
* Notice for setting Parade
- Depending on the setting values in Parade, PDR and Total PDR, MDRL will change.
- PDR (Payload Data Rate) : PDR represents how many bit-rate can be included as Ensemble bit-rate. If select
Ensemble to connect, T-Pump automatically calculate NoG minimum and NoG will increase NoG minimum.
It will print error message when calculated NoG minimum is over 8.
- Total PDR : Sum of Primary RS Frame`s PDR and Secondary RS Frame`s PDR.
- MDRL (Main Data Rate Loss) : TS bit-rate of current Parade. That represents how much the TS bit-rate in fixed
output TS bit-rate as 19.392Mbps takes . It depends on NoG values.
Parade GUI in T-Pump GUI
Parade GUI - Feature(1)
Parade GUI - Feature(2)
1
2