background image

WARNING - To reduce the risk of FIRE or INJURY:

1.  Luminaires and transformers to be installed by licensed electrical contractors.
2.  Luminaires to be used for intended purpose only. 
3.  Do not operate the luminaires with a missing or damaged parts.
4.  Use only genuine Lumascape parts to replace damaged or missing components.
5.  Refer to instructions for installation and operating requirements.
6.  Ensure installation complies with local regulations

Voltage insulation test (megger) will permanently damage product and will void warranty.
SAVE THESE INSTRUCTIONS.

SAFETY INSTRUCTIONS

IN0052 -  24 August 2016

Wiring Diagrams & Dip Switch Settings (Applicable to RGB & Single Colour Dimming with 24 V DC only)

RJ45 DMX WIRING

Wire# Wire Colour

DMX512 Function

1

white/green

data 1+

2

green

data 1-

3

white/orange Not Assigned

4

blue

Not Assigned

5

white/blue

Not Assigned

6

orange

Not Assigned

7

white/brown

GND

8

brown

Not Assigned

Drain

DMX IN

DMX OUT

CH1

CH2

CH3

X100 X10

X1

Copyright ©2016 Lumascape Lighting Industries Pty. Ltd.   ABN 21 010 572 773

www.lumascape.com.au

SWITCH SETTINGS

X100

X10

X1

Function

0

0

0

RDM address

0

0

1

DMX address / RDM capable 
but no writes (responds to 
rotary address)

5

1

0

Last address

9

9

0

0 output no DMX response

9

9

1

Ch1 100%

9

9

2

Ch2 100%

9

9

3

Ch3 100%

9

9

4

Ch1,2,3 0%

9

9

5

Ch1,2,3 100%

9

9

6

Ch1,2 100%

9

9

7

Ch2,3 100%

9

9

8

Ch1,3 100%

9

9

9

rainbow

Reviews: