WARNING - To reduce the risk of FIRE or INJURY:
1. Luminaires and transformers to be installed by licensed electrical contractors.
2. Luminaires to be used for intended purpose only.
3. Do not operate the luminaires with a missing or damaged parts.
4. Use only genuine Lumascape parts to replace damaged or missing components.
5. Refer to instructions for installation and operating requirements.
6. Ensure installation complies with local regulations
Voltage insulation test (megger) will permanently damage product and will void warranty.
SAVE THESE INSTRUCTIONS.
SAFETY INSTRUCTIONS
IN0052 - 24 August 2016
Wiring Diagrams & Dip Switch Settings (Applicable to RGB & Single Colour Dimming with 24 V DC only)
RJ45 DMX WIRING
Wire# Wire Colour
DMX512 Function
1
white/green
data 1+
2
green
data 1-
3
white/orange Not Assigned
4
blue
Not Assigned
5
white/blue
Not Assigned
6
orange
Not Assigned
7
white/brown
GND
8
brown
Not Assigned
Drain
DMX IN
DMX OUT
CH1
CH2
CH3
X100 X10
X1
Copyright ©2016 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
www.lumascape.com.au
SWITCH SETTINGS
X100
X10
X1
Function
0
0
0
RDM address
0
0
1
DMX address / RDM capable
but no writes (responds to
rotary address)
5
1
0
Last address
9
9
0
0 output no DMX response
9
9
1
Ch1 100%
9
9
2
Ch2 100%
9
9
3
Ch3 100%
9
9
4
Ch1,2,3 0%
9
9
5
Ch1,2,3 100%
9
9
6
Ch1,2 100%
9
9
7
Ch2,3 100%
9
9
8
Ch1,3 100%
9
9
9
rainbow