7
Figure 4
WARNING:
Improper connection of equipment grounding conductor can result in the risk of electrical shock.
Equipment should be grounded while in use to protect operator from electrical shock.
- Check with a qualified electrician if you do not understand grounding instructions or if you are in doubt as
to whether the tool is properly grounded.
-This tool is equipped with an approved cord rated at 230v and a 3-prong grounding type plug for you
protection against shock hazards.
-Grounding plug should be plugged directly into a properly installed and grounded 3-prong grounding-type
receptacle, as shown.
-Do not remove or alter grounding prong in any manner. In the event of a malfunction or breakdown,
grounding provides a path of least resistance for electrical shock.
OPERATION REGULATIONS
ATTENTION:
Make sure that the switch is in off position before adjusting the cutting depth, replacing or
adjusting the blades. Make sure the blade screws are securely tightened.
Assemble
stand with M6 hex nut, 6mm flat washer and carriage bolt. Then install the machine to the stand
and secure it with M8X30 hex bolt and 8mm flat washer
OVERLOAD PROTECTION
If the motor protection responds, this always indicates that the motor is overloaded. The cause must be
located and the fault eliminated.
If the motor is overloaded or in the event of power failure, the motor switches off automatically. The
machine can not be switched on again until the motor is cooled down or the power supply has been
restored.
SETTING ANGLE FENCE
Insert the socket head bolt into the slot A and B. Then loosen C to adjust angle fence.
Turn M down, guide fence can be moved to left or right.
Refer to figure 5