EN
15
Þ
Turning on the power supply of the meter while holding the button
– entering the software-update mode through RS485 interface
- Push-button increasing the value:
Þ
display of maximal value, The pressure of the push-button causes
the display of the maximal value during ca 3 seconds.
Þ
entry in the level of the parameter group,
Þ
moving on the chosen level,
Þ
change of the chosen parameter value – increasing the value.
- Push-button to change the digit:
Þ
display of minimal value, The pressure of the push-button causes
the display of the maximal value during ca 3 seconds.
Þ
entry in the level of parameter group,
Þ
moving through the chosen level,
Þ
change of chosen parameter value – shift on the next digit,
- Resignation push-button:
Þ
entry in the menu monitoring the meter parameters (press and
hold ca 3 seconds),
Þ
exit from the menu monitoring meter parameters,
Þ
resignation of the parameter change,
Þ
strict exit from the programming mode (press and hold
ca 3 seconds).
The pressure of the push-button combination
and hol-
ding down them during ca 3 seconds causes the deletion of alarm signa-
ling. This operation acts only when the support function is switched on.
The pressure of the push-button combination
causes
the erasing of the minimal value.
The pressure of the push-button combination
causes
the erasing of the maximal value.
The pressure and holding down the
push-button during ca 3
seconds causes the entry to the programming matrix. The program-
ming matrix can be protected by a safety code.
The pressure and holding down the
push-button during ca 3
seconds causes the entry to the menu monitoring meter parameters.