background image

LF2020-INS-LAB-RevG18 

3

1  INTRODUCTION

Congratulations on your purchase of the Lumex LF2020 Easy Lift Sit-to-Stand (STS) / 
LF2090 Bariatric Easy Lift Sit-to-Stand (STS). The following pages will provide you with important 
safety and operating instructions on the use of patient lifts, slings, and accessories, as well as 
maintenance and warranty information. Read this manual carefully before operating your patient 
lift and refer to it as often as needed. Consult your authorized distributor and/or healthcare 
professional with any questions or concerns regarding safe and effective techniques for operating 
your patient lift.
DO NOT attempt any transfer without prior approval of the patient’s healthcare provider. With 
their assistance, select the sling that best serves the needs, abilities, comfort and safety of the 
person being lifted. It is important that you use correct slings adapted to the body shape and 
weight and ability of the patient and the specific type of transfer needed.
Upon receipt of the patient lift, and prior to each use, inspect it closely to ensure that nothing 
is damaged, there are no loose or broken parts, that all patient lift parts are in the proper place, 
etc. Immediately replace any worn or broken components. Your patient lift should receive 
maintenance on a regular schedule and should be inspected daily for proper operation. Contact 
GF Technical Support at 1.770.368.4700 with any maintenance concerns.
Before lifting anyone, thoroughly read the instructions in this manual. Ideally, observe a team of 
trained experts performing the lifting procedures. The operator should then practice the entire 
lifting procedure several times with proper supervision and with a capable individual acting as 
patient. It is extremely important to know how a patient will feel in the patient lift. We suggest that 
the operator try all the various lifting slings and equipment until the operator is confident with 
how the patient lift operates. The lifting procedures should be explained to the patient before the 
actual lifting. Remember that safety requires the constant attention of the lift occupant and the 
operator. Use extreme care and common sense when operating a patient lift.
This guide covers the use of the LF2020 Easy Lift STS / LF2090 Bariatric Easy Lift STS. Keep in mind 
that the basic safety procedures included in this manual are to be used as a guide only. You may find it 
necessary to develop your own unique methods for safely utilizing the patient lift. Again, consult your 
healthcare professionals for their recommendations and never hesitate to ask for their assistance.

Info: Before attempting to assemble the patient lift, refer to the section titled “ASSEMBLY 

INSTRUCTIONS” contained elsewhere in this manual. Contact GF Tech Support at 

1.770.368.4700 or your GF authorized distributor if additional assistance is needed.
Info: In this manual, the person being lifted is referred to as the “patient” or “occupant” and 

the person operating the patient lift is called the “operator” or “attendant”.

Intended use

The Lumex LF2020 Easy Lift STS / LF2090 Bariatric Easy Lift STS is intended to aid in the transfer 
of an individual who is unable to independently transfer between bed, chair, bathtub, wheelchair, 
and/or commode.

 WARNING: The LF2020 Easy Lift STS / LF2090 Bariatric Easy Lift STS is designed for 

transfer only (to and from bed, chair, bathtub, toilet, wheelchair, commode etc.). This 

Patient Lift is not intended to be used for transporting or moving a patient from one 

location to another.

  WARNING: The LF2020 Easy Lift STS / LF2090 Bariatric Easy Lift STS is designed for use 

by individuals who can support the majority of their own weight. Special care must be 

taken with patients who cannot provide assistance while being lifted (i.e. such as patients 

who are comatose, spastic, agitated or otherwise severely disabled).

Summary of Contents for LF2020 Easy Lift STS

Page 1: ...LF2020 INS LAB RevG18 Read this manual before operating your Easy Lift Sit to Stand Save this manual for future use LF2020 EASY LIFT SIT TO STAND LF2090 BARIATRIC EASY LIFT SIT TO STAND USER MANUAL...

Page 2: ...TRANSPORTATION INSTRUCTIONS 7 5 ASSEMBLY INSTRUCTIONS 8 CHARGING THE BATTERIES 9 CHECKING BATTERY CAPACITY 9 ALARM BUZZERS 9 6 OPERATING INSTRUCTIONS 10 LIFTING THE PATIENT 11 7 CARE AND MAINTENANCE 1...

Page 3: ...est that the operator try all the various lifting slings and equipment until the operator is confident with how the patient lift operates The lifting procedures should be explained to the patient befo...

Page 4: ...te personal injury s NOTICE Indicates a potential hazard situation or unsafe practice that if not avoided could result in product or property damage Info Provides application recommendations or other...

Page 5: ...s in the sling WARNING Do not attempt to maneuver the lift by pushing on the mast boom actuator or patient Always maneuver the lift with the handle WARNING During lifting or lowering whenever possible...

Page 6: ...FEATURES EASY LIFT SIT TO STAND FEATURES Pendant Actuator Lifting Boom Knee Pad Footrest Base Brake Mast Control Box CONTROL BOX FEATURES RESET Button Battery Testing Battery Charger Plug In Actuator...

Page 7: ...s contents If damage is evident notify the carrier or your GF authorized distributor 2 Remove all loose packing from the carton 3 Carefully remove all the components from the carton Info Unless the pa...

Page 8: ...4 Attach boom to mast and hand tighten bolt and nut 5 Attach the L shaped arms to the back of the knee pad 6 Attach knee pad assembly to the mast 7 Place the control box in the bracket 8 Insert the ac...

Page 9: ...e control box Frequent plugging and unplugging of the pendant and actuator to and from the control box may damage the control box CHECKING BATTERY CAPACITY Info To check remaining battery capacity pre...

Page 10: ...ither open or closed position Preparation before lifting 1 Turn on the power by turning the RED RESET BUTTON clockwise 2 Press the pendant UP or DOWN button once 3 After the battery indicator lights d...

Page 11: ...raps to the hooks 5 Have the patient s hands holding the handles For patients who cannot hold the handles have them hold their arms around the chest 6 Press the UP button on the hand pendant 7 Before...

Page 12: ...ave them hold their arms around the chest 6 Press the UP button on the hand control 7 Before the patient s body is lifted from the chair stop and make sure the sling is secured and patient s knees are...

Page 13: ...0 368 4700 for further information When you believe a component or part is not functioning properly immediately contact GF Tech Support at 1 770 368 4700 as a potentially hazardous condition could exi...

Page 14: ...ting properly x x x Inspect all base hardware for wear x Mast Ensure that mast is fully engaged and locked into mast sleeve x x Inspect mast for bends or deflections x Inspect all mast hardware for we...

Page 15: ...operate even though battery indicator shows charge Battery charger still plugged in Poor connection between control box and pendant or defective pendant Poor connection between actuator and control bo...

Page 16: ...gth 50 Lifting height range Info As measured from sling hooks Minimum 27 Maximum 71 Range 35 Mast height 50 Maximum weight capacity LF2020 Easy Lift STS 400 lb EVENLY DISTRIBUTED LF2090 Bariatric Easy...

Page 17: ...NING WARRANTY SERVICE This limited warranty shall only apply to defects that are reported to the Distributor from whom the Customer purchased the product within the applicable warranty period If there...

Page 18: ...LOYEE OR INDEPENDENT CONTRACTOR WAGES PAYMENTS AND BENEFITS The warranties contained herein contain all the representations and warranties with respect to the subject matter of this document and super...

Page 19: ...spection 7 Intended use 3 Intended use contraindication 3 Introduction 3 L Lift and transfer from bed 11 Lift and transfer from chair 12 Lifting the patient 11 Lubrication 13 M Maintenance schedule 14...

Page 20: ...can be found on our website www grahamfield com 2005 GF Health Products Inc All Rights Reserved Graham Field and Lumex are trademarks of GF Health Products Inc One Graham Field Way Atlanta GA 30340 31...