14
ETL Model No.: HF1161
5. How to Wire Your Industrial Fan
(Continued)
WIRE
CONNECTORS
(Tucked Inside
Outlet Box)
Figure 22
5.9
After Connections have been made, turn Wires and
Connectors upward and carefully push them into the
Outlet Box.
Slide the Receiver completely onto the Hanger Ball,
nestled in the Hanger Bracket (Figure 22).
GND
SUPPLIED
WALL CONTROL
BLACK
BLACK
WHITE
BROWN
BROWN
GREY
HANGER BALL
GREEN WIRE (GROUND)
FROM HANGER BALL
TWO-CONDUCTOR
CABLE
(WITH GROUND)
BLACK
(HOT)
WHITE
SUPPLY
GROUND
TO
120-VOLT
SUPPLY
WHITE
BLUE
GREY
BLUE
GREEN WIRE (GROUND)
FROM HANGER BRACKET
HANGER BRACKET
GREEN GROUND
GREEN GROUND
Figure 23
5.10
Wiring Schematic for reference (Figure 23).
NOTE: See Section 7 (page 16) for Wall Control
Installation.
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
WARNING
!