Features

Isolation

Individual outlet protection

All ten outputs feature individual isolation and protection. This means that 
if a fault occurs on a piece of equipment connected to one output, fixtures 
on  the  other  outputs  are  totally  protected.  In  addition  the  input 
connectors have their own protection, this gives a double barrier between 
fixtures  and  the  console  and  protects  the  console  against  a  fault  on  the 
mains  supply  to  the  buffer  itself  (i.e.  if  the  buffer  unit  was  inadvertently 
connected across two phases).

1000 Volts optical isolation barrier

Each outlet has an optical isolator that is capable of withstanding voltages 
of  up  to  1000V.  Each  isolator  has  its  own  power  supply  eliminating  any 
direct electrical connection between outputs.
Self-healing technology makes sure that the  outlets can resist up to 530V 
over its data pairs. This means that after such a fault the outlet works fine 
again with normal DMX signals.

Short circuit protection

Each  outlet  is  protected  against  short  circuits,  or  incorrectly  wired 
connectors.

Modular isolation

All  the  components  that  provide  the  opto-isolation  are  built  into  a  single 
plug-in module for each channel making servicing ultra-simple. In addition 
each  module  is  completely  interchangeable  with  other  channels  including 
the input module.

Line voltage protection

Not  only  does  the  Hub  protect  your  various  pieces  of  equipment  from 
inadvertent  DMX-to-mains  connection  it  also  protects  itself.  Each 
individual  output  is  protected  so  that  no  damage  will  occur  to  the  buffer 
even if they are connected directly to 230V by mistake.
Even  a  built-in  rechargeable  battery  backups  the  complete  isolation 
functionality when a mains failure occurs (see “Power fail management”).

Page 10 of 12

DMX512-A 2.10 HUB

Summary of Contents for DMX512-A 2.10 HUB

Page 1: ...DMX512 A 2 10 HUB User Guide...

Page 2: ...n this documentation is supplied without warranty of any kind either directly or indirectly and is subject to change without prior written notice Luminex its employees or appointed representatives wil...

Page 3: ...vironmental 5 Connectivity 6 Rear panel 6 Mains 6 Front panel 6 DMX input 6 DMX output 7 Connection type 8 Features 9 Isolation 9 Individual outlet protection 9 1000 Volts optical isolation barrier 9...

Page 4: ...and such package shall be clearly and prominently marked to indicate that the package contains returned Product units or parts Accompany all returned Product units or parts with a written explanation...

Page 5: ...which zone it has to be connected This allows you to distribute 2 separate DMX lines 1024 channels in any possible output configuration All outputs can receive data as well and retransmit it on its s...

Page 6: ...n accordance with the following scheme Green Yellow Earth Blue Neutral Brown Live This equipment must be earthed Front panel DMX input Two Neutrik 5 pin gold plated male connectors are provided as zon...

Page 7: ...n be switched off when legacy DMX equipment is used that causes reflections on the DMX lines DMX output Ten Neutrik 5 pin gold plated female connectors are provided as output Connector Function Pin 1...

Page 8: ...above The unit can also be custom configured in any Enhanced Function topology EF 1 4 as described in BSR E1 11 the USITT DMX 512 A standard Contact Luminex LCE for more detail Following tables show y...

Page 9: ...DMX512 A 2 10 HUB Page 9 of 12...

Page 10: ...es sure that the outlets can resist up to 530V over its data pairs This means that after such a fault the outlet works fine again with normal DMX signals Short circuit protection Each outlet is protec...

Page 11: ...ogic This allows us to assure a maximum data delay between incoming data and outgoing data of 1 micro second Power fail management An integrated power management circuit assure optimal power condition...

Page 12: ...o external mains supply Working on battery power Battery status bad OUT No external mains supply Battery dead empty Or unit is switched off Support Spare part area Since serial LUM0060111and upwards a...

Reviews: