background image

Zone A and Zone B input connectors are also provided at the rear of the 
device. These inputs are straight through connections of the inputs on the 
front  and  allow  input  cabling  at  the  back  or  inside  a  rack.  All  5  pins  are 
connected  to  the  front  inputs  and  can  serve  as  a  real  non  isolated 
through.

On the front panel, a small switch at each input is provided to disable the 
bidirectional  functionality  of  each  zone  independently.  This  is  can  be 
switched off when legacy DMX equipment is used, that causes reflections 
on the DMX lines.

DMX output

Ten Neutrik 5 pin gold plated female connectors are provided as output.

Connector

Function

Pin 1

Signal common (0 volt)

Pin 2

Data complement (-)

Pin 3

Data true (+)

Pin 4

Not used

Pin 5

Not used

All  outputs  are  compliant  with  the  DMX512-A  specification  and  are 
terminated. The outputs are  separately  optical  and  galvanic isolated from 
the inputs and from each other.

A tiny switch is provided with every output to choose between Zone A and 
Zone B. In this way you can make any combination of splitter, configuring 

DMX512-A 2.10 HUB

Page 7 of 12

Summary of Contents for DMX512-A 2.10 HUB

Page 1: ...DMX512 A 2 10 HUB User Guide...

Page 2: ...n this documentation is supplied without warranty of any kind either directly or indirectly and is subject to change without prior written notice Luminex its employees or appointed representatives wil...

Page 3: ...vironmental 5 Connectivity 6 Rear panel 6 Mains 6 Front panel 6 DMX input 6 DMX output 7 Connection type 8 Features 9 Isolation 9 Individual outlet protection 9 1000 Volts optical isolation barrier 9...

Page 4: ...and such package shall be clearly and prominently marked to indicate that the package contains returned Product units or parts Accompany all returned Product units or parts with a written explanation...

Page 5: ...which zone it has to be connected This allows you to distribute 2 separate DMX lines 1024 channels in any possible output configuration All outputs can receive data as well and retransmit it on its s...

Page 6: ...n accordance with the following scheme Green Yellow Earth Blue Neutral Brown Live This equipment must be earthed Front panel DMX input Two Neutrik 5 pin gold plated male connectors are provided as zon...

Page 7: ...n be switched off when legacy DMX equipment is used that causes reflections on the DMX lines DMX output Ten Neutrik 5 pin gold plated female connectors are provided as output Connector Function Pin 1...

Page 8: ...above The unit can also be custom configured in any Enhanced Function topology EF 1 4 as described in BSR E1 11 the USITT DMX 512 A standard Contact Luminex LCE for more detail Following tables show y...

Page 9: ...DMX512 A 2 10 HUB Page 9 of 12...

Page 10: ...es sure that the outlets can resist up to 530V over its data pairs This means that after such a fault the outlet works fine again with normal DMX signals Short circuit protection Each outlet is protec...

Page 11: ...ogic This allows us to assure a maximum data delay between incoming data and outgoing data of 1 micro second Power fail management An integrated power management circuit assure optimal power condition...

Page 12: ...o external mains supply Working on battery power Battery status bad OUT No external mains supply Battery dead empty Or unit is switched off Support Spare part area Since serial LUM0060111and upwards a...

Reviews: