Zone A and Zone B input connectors are also provided at the rear of the
device. These inputs are straight through connections of the inputs on the
front and allow input cabling at the back or inside a rack. All 5 pins are
connected to the front inputs and can serve as a real non isolated
through.
On the front panel, a small switch at each input is provided to disable the
bidirectional functionality of each zone independently. This is can be
switched off when legacy DMX equipment is used, that causes reflections
on the DMX lines.
•
DMX output
Ten Neutrik 5 pin gold plated female connectors are provided as output.
Connector
Function
Pin 1
Signal common (0 volt)
Pin 2
Data complement (-)
Pin 3
Data true (+)
Pin 4
Not used
Pin 5
Not used
All outputs are compliant with the DMX512-A specification and are
terminated. The outputs are separately optical and galvanic isolated from
the inputs and from each other.
A tiny switch is provided with every output to choose between Zone A and
Zone B. In this way you can make any combination of splitter, configuring
DMX512-A 2.10 HUB
Page 7 of 12