TYPES OF MODES:   

SINGLE way mode.     TWO WAY mode.           MIMIC mode.

 

No jumper 
for SINGLE 
way mode 

Jumper top two 
pins for TWO 
WAY mode 

Jumper bottom 
two pins for 
MIMIC mode 

POSITIONING & WIRING. 

IMPORTANT:   All wiring must be carried out by a qualified electrician in  
accordance with IEE and part P regulations.    
 

This product is IP65 rated and may be fitted outdoors.   Choose a suitable position for 
easy wiring but make sure that the aerial is clear of obstructions and metal objects. 
The cable glands must face down and the aerial skywards. 
 
Remove the circuit board from the enclosure by first unscrewing the aerial and ground 
terminals and removing the aerial cable.   Now unscrew the three fixing screws as shown 
in Fig 1 and remove the whole circuit board.   Fix the enclosure using countersunk 
screws through the screw cups on the base of the enclosure.   Seal these screws with a 
suitable waterproof sealant to maintain the IP rating of the enclosure.   Re-fit the board 
and connect the aerial cable making sure that the screen connects to the ground terminal 
as shown in Fig 2. 

 

This product is powered from mains voltage 230V 50Hz and can switch up to a maximum 
of 2KW resistive shared over four relays.   Each relay has a switched 230V Live output 
and has a maximum 1KW  resistive switch capacity.  EG: If two relays are switching 1KW 
each then the remaining relays cannot be used.   Alternatively all four relays can be used 
up to a maximum of 500W each. 
 
The mains supply should be from a fused spur or consumer unit and be fused correctly 
according to the load. Do not fuse above 8amps.   
Pass a round 1.5mm flex through the left hand gland and tighten to provide cable  
restraint and a waterproof seal.    Maximum outside diameter 8mm.  
Connect the 230 volts LIVE and NEUTRAL to the MAINS IN terminal as shown. 
 
For each channel that is to be used, slacken one of the glands and remove the bung to 
enable round 1.5mm cable to be passed through.   Tighten the gland to provide a  
waterproof seal and cable restraint.   Connect the cable to one of the four channel  
outputs as shown.   Ensure that the load does not exceed the maximum rating. 
 
The EARTH block is common and purely used as a convenient means of connecting all 
the earths. 