background image

GX30

-

Globe 

 

Hard Wired PIR Detector Installation Handbook

   

 

Page 7.

 

Contact A polarity

 

Switch 9

 

N/O

 

OFF

 

N/C

 

ON

 

Contact B polarity

 

Switch 10

 

N/O

 

OFF

 

N/C

 

ON

 

Contact B Time

 

Switch 7

 

Switch 8

 

1 second

 

OFF

 

OFF

 

30 seconds

 

OFF

 

ON

 

2 minutes

 

ON

 

OFF

 

5 minutes

 

ON

 

ON

 

Switch setting table

 

 

PIR detection range

 

Detection range can be increased or decreased from 10 metres to 30 metres as preferred.

 

Increasing the range will also increase the risk of false detection and should only be used 
in quiet stable locations.

 

Where the PIR can detect passing vehicles or pedestrians, it is useful to decrease the  
sensitivity which will shorten the detection range.

 

An alternative solution is to angle the lens down which will keep the same sensitivity but 
will be physically limited in range.

 

 

 

Pulse count

 

The normal pulse count setting is 2 but may be increased up to 4 for environment's where 
there is a lot of incidental movement of foliage.  Increasing this setting will affect rang.       
1 pulse count can be used and will increase range but with a slightly higher risk of false 
alarms.

 

 

Walk test

 

Switch this on for a super bright red LED which will assist when walk testing the area to be 
covered.  This feature may be left on if preferred.

 

 

Contact B Day/Night

 

Switch this on if relay A is only to work between dusk and dawn.

 

Contact B Time

 

The contact duration is adjustable from 1 second to 5 minutes for this relay only.

 

Contacts A and B polarity

 

Both relay contacts A and B can be independently set to normally closed N/C or normally 
open N/O

 

Summary of Contents for GX30 Globe

Page 1: ...12 Volt Hard Wired PIR Detector Installation Handbook 2a BELLEVUE ROAD FRIERN BARNET LONDON N11 3ER Tel 0044 0 208 368 7887 Fax 0044 0 208 368 3952 Type GX30 Globe Issue 1 ...

Page 2: ...erful microprocessor which uses logic to determine the validity of an activation By combining this technology with the specially designed pet immune Fresnel lens nuisance alarms are all but eradicated The PIR also contains front and rear anti tamper to detect removal from the wall and unauthorised adjustment Multi beam alignment masking The multifunction lens produces 7 long range beams and 7 medi...

Page 3: ...are tamper feet are provided One is 1mm longer and the other is 2mm longer than the original The tamper foot is a push fit and can be removed by carefully pulling it from the pin Template Fixing holes Cable holes Optional tamper cup Choose a flat surface facing approximately in the direction to be monitored Using the template drill the wall to accept two fixing screws the cable entry and tamper cu...

Page 4: ...adjusted up to 5 minutes and it can if required be gated with the light sensor so that it will only operate between dusk and dawn Switch capacity max 1 amp 24 volts Warning Do not apply mains voltage to any part of this product The functionality of contact B is meant only to serve independent equipment that is designed to switch mains lighting such as a power relay in accordance with IEE regulatio...

Page 5: ...detector module according to the table below MULTIBEAM OPTIMUM HEIGHT 2 METRES RANGE Maximum MODULE TILT 0 DEGREE 0 DEGREE MULTIBEAM HEIGHT 6 METRES RANGE Maximum MODULE TILT 9 DEGREE 9 DEGREE PET IMMUNITY HEIGHT 1 5 METRES RANGE Maximum MODULE TILT 2 DEGREE 2 DEGREE CURTAIN COVERAGE HEIGHT 6 METRES RANGE Maximum MODULE TILT 45 DEGREE 45 DEGREE 6 Mask this section off for pet ally applica tions Ma...

Page 6: ...have the following functions PIR detection range Pulse counting Walk Test Light sensor Contact time Contact polarity ON 1 2 3 4 5 6 7 8 9 10 PIR range Switch 1 Switch 2 20m OFF OFF 30m ON ON 15m OFF ON 10m ON OFF Pulse count Switch 3 Switch 4 2 Pulse OFF OFF 1 Pulse ON ON 3 Pulse OFF ON 4 Pulse ON OFF Walk test Switch 5 OFF OFF ON ON Contact B day night Switch 6 Works always OFF Night only ON ...

Page 7: ...lution is to angle the lens down which will keep the same sensitivity but will be physically limited in range Pulse count The normal pulse count setting is 2 but may be increased up to 4 for environment s where there is a lot of incidental movement of foliage Increasing this setting will affect rang 1 pulse count can be used and will increase range but with a slightly higher risk of false alarms W...

Page 8: ... stated in EU directive 2002 95 EU annex CE Directive 2004 108 EC CE Directive Herby Luminite declares that this product is in compliance with the CE essential require ments and other relevant provisions of Directive 2004 108 EV MADE IN ENGLAND LUMINITE ELECTRONICS LTD 2a Belevue Road London N11 3ER Tel 0044 0 208 368 7887 Fax 0044 0 208 368 3952 Web www luminite co uk Supply 12V DC Power consumpt...

Reviews: