GX 30 Globe Technical specifications

 

 

 
 

Regulatory information

 

Supplier:  Luminite Electronics Ltd, 2a Bellevue Road, London N11 3ER.

 

Weee Directive 2002/95/EC (Weee directive) Products marked with this symbol cannot be disposed of as unsorted municipal waste in 
the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment or 
dispose of it at a designated collection point. For more information see: www.recyclethis.info

 

RoHs Directive: 2002/95/EC RoHs Complient. Hereby Luminite declares that this device does not contain lead, mercury, cadmium, 
hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated depheny eithers (PBDE) in more than one percent specified 
by EU directive 2002/95/EC, except exemptions stated in EU directive 2002/95/EU annex.

 

CE Directive 2004/108/EC (CE Directive): Herby, Luminite declares that this product is in compliance with the CE essential require-
ments and other relevant provisions of Directive 2004/108/EV.

 

 

MADE IN ENGLAND

 

LUMINITE ELECTRONICS LTD

 

2a Belevue Road, London N11 3ER

 

Tel: 0044 (0) 208 368 7887  Fax: 0044 (0) 208 368 3952

 

Web:

 

www.luminite.co.uk

 

 

 

Supply

 

12V DC

 

Power consumption

 

17m/a 

 

Detection type

 

Passive Infrared Dual element pyro

 

Detection range

 

Programmable between 

 

10 and 30 metres

 

Mounting height

 

Variable up to 6 metres

 

optimum height 3 metres

 

Coverage

 

10

-

70°

 

Contact A

 

Volt free N/O or N/C – 1 second

 

Contact B

 

Volt free N/O or N/C  

 

1 second to 5 minutes

 

Light sensor

 

Applied to Contact B

 

Adjustment

 

180° pan + 90° tilt

 

Pulse count

 

1

-

4

 

Walk test facility

 

High intensity LED

 

Anti tamper

 

Front and rear

 

Temperature range

 

-

10 to +60°C

 

Weather rating

 

IP55

 

Enclosure

 

Durable ABS UV stabilised housing

 

Weight

 

300grams

 

Dimensions 

 

141 x 165.5 x 109mm

 

Summary of Contents for GX30 Globe

Page 1: ...12 Volt Hard Wired PIR Detector Installation Handbook 2a BELLEVUE ROAD FRIERN BARNET LONDON N11 3ER Tel 0044 0 208 368 7887 Fax 0044 0 208 368 3952 Type GX30 Globe Issue 1 ...

Page 2: ...erful microprocessor which uses logic to determine the validity of an activation By combining this technology with the specially designed pet immune Fresnel lens nuisance alarms are all but eradicated The PIR also contains front and rear anti tamper to detect removal from the wall and unauthorised adjustment Multi beam alignment masking The multifunction lens produces 7 long range beams and 7 medi...

Page 3: ...are tamper feet are provided One is 1mm longer and the other is 2mm longer than the original The tamper foot is a push fit and can be removed by carefully pulling it from the pin Template Fixing holes Cable holes Optional tamper cup Choose a flat surface facing approximately in the direction to be monitored Using the template drill the wall to accept two fixing screws the cable entry and tamper cu...

Page 4: ...adjusted up to 5 minutes and it can if required be gated with the light sensor so that it will only operate between dusk and dawn Switch capacity max 1 amp 24 volts Warning Do not apply mains voltage to any part of this product The functionality of contact B is meant only to serve independent equipment that is designed to switch mains lighting such as a power relay in accordance with IEE regulatio...

Page 5: ...detector module according to the table below MULTIBEAM OPTIMUM HEIGHT 2 METRES RANGE Maximum MODULE TILT 0 DEGREE 0 DEGREE MULTIBEAM HEIGHT 6 METRES RANGE Maximum MODULE TILT 9 DEGREE 9 DEGREE PET IMMUNITY HEIGHT 1 5 METRES RANGE Maximum MODULE TILT 2 DEGREE 2 DEGREE CURTAIN COVERAGE HEIGHT 6 METRES RANGE Maximum MODULE TILT 45 DEGREE 45 DEGREE 6 Mask this section off for pet ally applica tions Ma...

Page 6: ...have the following functions PIR detection range Pulse counting Walk Test Light sensor Contact time Contact polarity ON 1 2 3 4 5 6 7 8 9 10 PIR range Switch 1 Switch 2 20m OFF OFF 30m ON ON 15m OFF ON 10m ON OFF Pulse count Switch 3 Switch 4 2 Pulse OFF OFF 1 Pulse ON ON 3 Pulse OFF ON 4 Pulse ON OFF Walk test Switch 5 OFF OFF ON ON Contact B day night Switch 6 Works always OFF Night only ON ...

Page 7: ...lution is to angle the lens down which will keep the same sensitivity but will be physically limited in range Pulse count The normal pulse count setting is 2 but may be increased up to 4 for environment s where there is a lot of incidental movement of foliage Increasing this setting will affect rang 1 pulse count can be used and will increase range but with a slightly higher risk of false alarms W...

Page 8: ... stated in EU directive 2002 95 EU annex CE Directive 2004 108 EC CE Directive Herby Luminite declares that this product is in compliance with the CE essential require ments and other relevant provisions of Directive 2004 108 EV MADE IN ENGLAND LUMINITE ELECTRONICS LTD 2a Belevue Road London N11 3ER Tel 0044 0 208 368 7887 Fax 0044 0 208 368 3952 Web www luminite co uk Supply 12V DC Power consumpt...

Reviews: