The Lumiscope Co., Inc

www.lumiscope.net

Repair Department: 1-800-672-8293

Made and Printed In China

Model 1134
AccuRead

Blood Pressure Monitor & Clock

User Manual

Summary of Contents for AccuRead 1134

Page 1: ...Distributed by The Lumiscope Co Inc www lumiscope net Repair Department 1 800 672 8293 Made and Printed In China Model 1134 AccuRead Blood Pressure Monitor Clock User Manual ...

Page 2: ......

Page 3: ...re equivalent to those obtained by a trained observer using cuff stethoscope auscultation method within the limits prescribed by the American National Standard Electronic or Automated Sphygmomanometers Please read this manual carefully before use For specific information on your own blood pressure contact your physician Please be sure to keep this manual Table of Contents Introduction 3 How This M...

Page 4: ...the pressure oscillations during the deflation process your 1134 will determine the systolic and diastolic pressures for you and your pulse rate is detected at the same time What is Blood Pressure Blood pressure is the pressure exerted on the artery tube while blood flows through the arteries The pressure measured when the heart contracts and sends blood out of the heart is systolic highest blood ...

Page 5: ...s KPa 1 2 3 4 AVG Start Power Pre formed Cuff Memory Zone Select Air Tube Average Selection USB Plug PC Link Memory Select Cuff Plug Outlet WHO Indicator AC Adaptor Outlet Display Symbols Systolic Pressure Diastolic Pressure Pulse Value Date Time ...

Page 6: ...omatically turns off in 3 minutes power saving Operated by 4 AA batteries or AC DC adapter Note This unit also offers PC LINK software If you order this function you will receive a separate package including a CD and a connection line with a USB plug You may order this accessory at our website www lumiscope net Unit Display Explanation Features User 1 4 Appears when the unit is being operated by U...

Page 7: ...Fig A Note The level of your heart is slightly below your armpit Relax your entire body especially the area between your elbow and fingers 2 If the cuff is not at the same level as your heart or if you can not keep your arm completely still throughout the reading use a soft object such as a folded towel to support your arm Fig B Do not allow hard objects to come in contact with the wrist cuff 3 Tu...

Page 8: ... Position the artery mark over the main artery on the inside of your arm in the upper arm Note To locate the main artery press two fingers approximately 1 2cm above the bend of your elbow on the inside of your left arm D To have a secure fit pull the end of the cuff towards you wrap it over then press it for closure If the Index line falls within the OK range indicated at the edge of the cuff this...

Page 9: ...Pressure Deflating Blood Pressure Reading Showing levels of Blood Pressure Reading Standards for assessing high blood pressure without regard to age have been established by the World Health Organization WHO as shown in the chart as below This unit offers 6 color light signs after user s measuring From the light sign it will help users to find out their health situation Different levels show the c...

Page 10: ...hat alerts the user to the presence of an irregular heartbeat Irregular Heartbeat reading When taking your blood pressure reading If you are experiencing an irregular heartbeat the unit will display the Pulse Value and IH symbols alternately Example 90 IH Note It is advised that you consult your physician if the irregular heartbeat symbol IH appears often Regular Heartbeat reading but above normal...

Page 11: ...usly measured values A Push the PAGE button to select one of the four Memory Zones B Once one of the four Memory Zones have been selected Push the AVG button twice The average for the Hour will be displayed AVG C To view the averages for the Day Week Month All keep pushing the AVG button D To view another Memory Zone push the PAGE button once then push the AVG button to view the averages AVG AVG A...

Page 12: ... the Date Time accordingly B The LCD display blinks the word ON You may press and adjust desired time for the alarm by pressing the MEMO or PAGE buttons C Keep LCD display in the ON position and press button to continue second alarm setting D If you need to stop alarm setting you may press MEMO or PAGE buttons to let the LCD display transfer to the OFF position Then the Alarm setting will stop Clo...

Page 13: ...been positioned correctly Replace the batteries with new ones Re insert the batteries in the correct position Err P shown on LCD Fails to inflate Make sure the cuff is connected to the unit properly Check air tube If broken replace it Err 1 shown on LCD Deflates too fast Return for servicing Err 2 shown on LCD Movement has occurred Signal interference around BPM Keep still when taking measurement ...

Page 14: ...t are beyond the control of Lumiscope Lumiscope shall not be responsible for any type of incidental consequential or special damage All implied warranties including but not limited to those implied warranties of fitness and merchantability are limited to the total duration of two years from the original date of purchase To obtain warranty service on your Lumiscope Blood Pressure Monitor please con...