SY Series EOS Driver Integrated System
4
DRIVER / PSU INSTALLATION
1. Select a suitable location to mount the driver / PSU. This should be in a dry location, with free airflow
around the driver.
2. The driver should be mounted onto an flat surface.
3. Use the mounting holes at either end of the case to secure the driver.
4. Each driver / PSU must be connected to a fuse panel or RCD breaker.
6. Refer to the wiring example at the beginning of this manual for further guidance.
7. Plug the light into the driver
8. Refer to the EOS controller manual for setup instructions.
AC / DC POWER SUPPLY - DIMENSIONS AND CONNECTIONS
Input Voltage: 100 - 240 V AC
Output Voltage: 24 V DC
Output Current: 10A (Max)
IP 67 Rated Case
Ensure correct electrical polarity. Incorrect installation will invalidate warranty!
Note: Care must be taken when plugging in the light to the driver module as the connectors are keyed and
if forced may bend/brake a pin on the connector.