Planning the Installation (802 & 1602)
Bonding Attention: Failure to bond the lights properly and maintain the appropriate protection will invalidate
the LUMISHORE warranty.
LUMISHORE lights should be connected to the vessel’s DC Bonding system to ensure protection from electrolytic /
galvanic corrosion. All bonding connections should be fully checked prior to returning the vessel to the water.
LUMISHORE lights have integrated circuitry to protect lights from external issues, but these are dependent upon
correct bonding.
Installation into a metal or carbon fibre hull requires an isolation sleeve kit.
Installation Considerations:
• Location - Positioning will be dependent on both external and internal obstacles; consideration should be given to
installation wiring and internal access within the vessel. Ideally the light modules should be installed 6” to 10”
(150-250mm) below the water line and spaced between 2.5ft to 6.5ft (0.8-2m) apart.
• Select a flat surface; make sure that both the internal and external surfaces of the hull are even and parallel. It may
be necessary to sand or grind the surface.
• A hole will be drilled to allow the Thru-Hull light to be inserted; care must be taken to ensure there is unrestricted
access inside the hull
• The light is temperature sensitive and must not be located close to the exhaust or other heat sources.
• If multiple lights are installed, each light should be evenly spaced to ensure the best water illumination. The number
of lights and the spacing on your vessel will depend on a few factors: vessel size, location of lights and water clarity.
Metal or Carbon Fibre Hull Isolation Kit
Model
TIX802
TIX1602
Part Number
60-0211
60-0212
5