45-0183 - Rev 1.0
2
Electrical Installation
www.Lumishore.com
Lumishore UK Unit 2, Technium 1, Kings Road, Swansea, SA1 8PH, UK | +44(0)208 144 1694 | Info@Lumishore.com
Cleaning and Maintenance
The light cables can be extended. Ensure the correct cable gauge is
used to avoid issues with voltage drop. Follow ABYC recommenda-
tions for no more than 3% voltage drop. Consult a qualified electrical
installer, or contact Lumishore for further information.
Make sure the lights are tested, and working as expected before the
boat goes back in the water.
Battery
Red
(+VDC)
Red
(+VDC)
Black
(GND)
Fuse
Fuse
Switch
Off
On
Fuse or
Circuit
Breaker
LUMISHORE Ltd warrants the TIX 404 to be free from defects in
workmanship and materials for a period of three years, starting
from the date of original purchase. Misuse, abuse, improper instal-
lation, neglect, improper shipping, damage caused by disasters
such as fire, flood, and lightning, installation by unqualified
personnel, unauthorized repair or modification will void this
warranty. For the avoidance of confusion and doubt, non-compli-
ance with all installation, maintenance and operating instructions
in this document constitute non-conformance with warranty
terms
.
Warranty
LUMISHORE lights require simple cleaning. Lights should be
checked often to ensure the light body and lens area are free from
sea growth. In the event that your light requires cleaning, we
recommend the use of a soft cloth or soft bristled brush.
• DO NOT use any abrasive cleaning materials as these may
damage the body of the light.
• DO NOT use any cleaning fluids that contain solvents, acids or
alkalis.
• DO NOT clean using pressure washing or sandblasting equip-
ment.
Slight discolouration of body may occur over life. This does not
affect performance, and is not subject to warranty.
Due to nature and high build quality it may on rare occasions be
possible to see small levels of condensation, this is normal for high
power LEDs and will disappear after cooling and does not harm
operation in any way.
If the lights are covered for any reason, e.g maintenance, or paint-
ing DO NOT switch the lights on until the covers are removed.
Plan the cable route prior to installation. Ensure all cables are correctly
rated. Each light must be individually fused. The cable connections
are:
Red
12V or 24 V DC
Black
Ground
The fuse ratings are:
12 V DC
6A
24
V
DC
4A
The lights have a simple ON / OFF operation, and will come on in
either White, or Blue depending on the model.
All connections must be made waterproof.
88mm (3.47in)
LED ARRAY SHOWN
FOR ILLUSTRATION
PURPOSES ONLY
55mm
(2.17in)
144mm
(5.67in)
8mm
(0.32in)
136mm
(5.35in)