ELECTRICS
80
Fault
Possible Cause
Proposed Fix
Reverse Polarity
Mains Supply reversed?
The reverse polarity light is designed to illuminate when the Live and Neutral supply has been reversed/crossed over. If the light illuminates
light is
there is a problem with the site supply or the cable connecting the supply to your vehicle. The light is designed to work on UK electrical
illuminated on PSU
supplies (where the neutral conductor is connected to earth at the sub station). If you are using your vehicle outside the UK this light may
illuminate when no fault exists. In these cases consult the site warden for advice.
Generator being used
‘The Reverse Polarity warning light is on when using my Generator’.
This is a normal side effect when using some types of generator. Instead of connecting the neutral conductor to earth, some generators
centre tap the earth connection making both neutral and live conductors 110V above earth. This 110V difference causes the neon polarity
indicator to illuminate. In most cases it is still safe to use the generator, but please consult the generator handbook for further information.
Control Panel
Control panel has no
Backlight/illumination may have switched off. Press the select button to reactivate the backlight.
problems
display
Check batteries and fuses, turn PSU shutdown switch and charger switch on and ensure mains supply is connected.
Check control panel connecting lead at PSU and behind Control Panel. Contact your Dealer
12v Power turns off
Battery protect feature has operated to protect the Vehicle battery and or the Leisure battery. See 3.8
Engine has been started, all equipment has been disconnected to meet EMC requirements. See 2.7
Control panel locked/
Observe control panel handling instructions.
erratic function
Control panel software may have crashed. Reboot control panel by turning off the PSU isolate switch. Wait 30 seconds then turn the
switch back on.
No 12 volt output
No 230V supply
Check all above.
from PSU
Charger not switched on
Turn charger switch on, switch will illuminate
Battery not connected and Install charged battery as per ??
/ or charged
Power button on control
Turn power on at control panel
panel not switched on
Battery flat / Battery fuse
Recharge battery, check fuses, check charging voltage is present at battery.
blown
Fuse blown
Check all fuses are intact and the correct value fuse is installed as per fuse table
Equipment switched off /
Check equipment is switched on and connected to the 12V supply.
unplugged
3.10
Common Fault Table (continued)
Summary of Contents for ALARIA 2018
Page 14: ...PREPARING FOR THE ROAD 14 Fig 6 Checking Left Right Friction Pads...
Page 18: ...PREPARING FOR THE ROAD 18 Fig 5 Fig 6 Fig 9 Fig 8 Fig 7 Fig 10...
Page 46: ...ON THE ROAD 46...
Page 51: ...51 SERVICES SERVICES Water 52 Gas 59 Electricity 64...
Page 66: ...SERVICES 66...
Page 67: ...67 ELECTRICS ELECTRICS Power Control System 68 Battery 74 Fuses 78 Technical Data 85...
Page 86: ...ELECTRICS 86...
Page 118: ...118 FLYSCREENS BLINDS ROOFLIGHTS Opening and closing the panoramic rooflight...
Page 126: ...126...
Page 127: ...127 AL KO CHASSIS TYRES AL KO CHASSIS TYRES Chassis 128 General Maintenance 129 Tyres 130...
Page 132: ...GENERAL DATA 132 ALARIA...
Page 133: ...133 GENERAL DATA ALARIA...
Page 134: ...GENERAL DATA 134 ALARIA...
Page 135: ...135 GENERAL DATA ALARIA...
Page 136: ...GENERAL DATA 136 ALARIA...
Page 137: ...137 GENERAL DATA ALARIA...
Page 144: ...GENERAL DATA 144...