© PROPERTY OF LUNDIX IT SWEDEN, ALL RIGHTS RESERVED – THE DISCLOSURE OR OTHER COMMUNICATION, COPYING, REPRODUCTION AND ANY USE WHATSOEVER IS FORBIDDEN WITHOUT THE WRITTEN AUTHORIZATION
OF LUNDIX IT.
SPC SmartBox User Manual
Revision
1.1
Page
15 of 62
Reference
2017-110
4.2
Z-Wave Configuration
4.2.1
Configuring Z-Wave Network
Z-Wave devices are managed in
Configuration->Z-Wave Network
.
Element
Type
Description
Id
Number
Z-Wave Node Id (unique id assigned by Z-Wave Gateway)
Name
Text
Device name (Default Device_Id. Can be changed in the details form)
Product
Text
Vendor, Product Name and a short description
Status
Text
Shows if the device is alive (
OK
) or is unreachable (
Failed
). Normal mode
for battery operated devices is
Sleeping
.
Update Device Status
Button
Click for updating device status
Battery
Number
Battery status (0-100%). Only available for battery operated devices.
Details
Button
Button to open device detail page
Update Route
Button
Button to request rerouting of the device
Request Status
Button
Button to request status of the device (send a NIF)
Remove Failed
Button
Button to remove a failed node. Only enabled if the device is considered
failed. NOTE! If you would like to remove a working device from the
network please use the exclusion procedure instead.
Start Inclusion
Button
Button to include (add) a new devices
Start Exclusion
Button
Button to exclude (remove) a device
Reset Z-Wave Network
Button
Button to reset the Z-Wave network to factory state.
Warning! All Z-
Wave devices will be removed
. To be able to include them again you
had to exclude them first.
Rebuild Network Topology
Button
Button to rebuild the network.
NOTE!
Please do not use the physical Z-Wave push button
on the SPC SmartBox device to include
or exclude devices, because then you have no chance to see what is happening during the
inclusion/exclusion. Probably the button will be disabled in the future.